Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 030F2844 Cty SAC Rte 99 PM 7.1/9.4 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Masoud Saed |
Date Reported: |
05/25/2021 |
|
Address: |
TL Number: |
197308 |
||
City: |
||||
Project Name: Construct new PCC precast girder bridge over UPRR at McConnell OH between existing SB and NB alignments |
||||
Prime Contractor: GRANITE CONSTRUCTION COMPANY |
||||
Sample Taken Date: |
04/26/2021 |
Mix Design: |
Unknown |
|
Contractor: Unknown |
Location : |
|||
Structure unique identifier: |
||||
Structure name: McConnell barrier 842 |
||||
Location of Pour: |
The following testing has been tested in accordance with:
ASTM C39-10 : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Cross sectional area of cylinder (in^2) | Average diameter of cylinder (in) | Compressive strength of cylinder (psi) | Maximum load on cylinder (lb) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 12.57 | 4.00 | 5180.0 | 65094 | 2 |
2 | 12.57 | 4.00 | 4940.0 | 62075 | 1 |
3 | 12.57 | 4.00 | 4968 | 62429 | 1 |
DIME Test ID: 2021-04-26-13-1
Number of specimens: 3
Compressive strength (to nearest 10 psi): 5030
Age of specimen: 28 days
Certified By: Mike Mullins
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing