Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 030H4604 Cty PLA Rte 80 PM 2.6/3.1 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Justin Kunert |
Date Reported: |
05/20/2021 |
|
Address: |
TL Number: |
79278 |
||
City: |
||||
Project Name: WIDEN ON-RAMP AND REPLACE BRIDGE. |
||||
Prime Contractor: Myers & Sons Construction |
||||
Sample Taken Date: |
04/22/2021 |
Mix Design: |
C71A4A1 |
|
Contractor: Unknown |
Location : PLACER COUNTY IN ROSEVILLE AT THE ATLANTIC STREET ON RAMP |
|||
Structure unique identifier: |
||||
Structure name: Stage 1 Abut 1 Wall |
||||
Location of Pour: |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 6.01 | 28.37 | 116708 | 4114.0 | 1 |
2 | 6.02 | 28.46 | 114069 | 4008.0 | 1 |
DIME Test ID: 2021-04-22-15-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 4060
Age of specimen: 7 days
Certified By: Mike Mullins
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 6.00 | 28.27 | 136601 | 4831.0 | 1 |
2 | 6.01 | 28.37 | 136242 | 4803.0 | 1 |
DIME Test ID: 2021-04-22-15-2
Number of specimens: 2
Compressive strength (to nearest 10 psi): 4820
Age of specimen: 28 days
Certified By: Mike Mullins
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing