Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 44444 DEA: ASCP EFIS: ASCP
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for submitting Sample information for Asphalt Supplier Certification Program.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2021-03-24-20
TL Number from the TL Form:
Sample Submitted By Organization: Veleroo - Coolidge
Sample Organization Contact: 111-111-1111
Type of Sample: Quality Control
Type of Material: Asphalt Binder
Sample Taken Date: 03/24/2021
Date that the sample was received by the laboratory/organization performing the testing: 03/24/2021
The quantity of what the sample constitutes: 1 of 2 split sample
A brief description of the sample: COC asphalt binder
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Western Emulsions Inc
Performance Grade: PG 70-10
Modified: No
Lot number:
Sublot number:
Tank number: 25K3
Time of sample: 8:00AM
HMA Supplier:
Certified Asphalt Supplier: Valero Coolidge - Coolidge AZ
Multigrade:
Multigrade Type:
Asphalt Binder Mix Number:
DIME Test ID: 2021-03-24-20-1
Test Method: AASHTO T316-17: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Verified Date: 04/05/2021
Date Tested: 03/24/2021
Submitted By Organization: Veleroo - Coolidge
Organization Address: 123 Abc Street,
Organization City: Coolidge
Organization State: AZ
Organization Zipcode: 88888
Organization Email: binderlab1@gmail.com
Organization Phone: (111) 111-1111
General Comments for this Test: need to verify torque
Test Result Compliance:
Additional Comments When Verified:
Is viscosity reading in cP/Pa-s?
|
Pa-s
|
Time of test
|
10:00 HH:MM
|
Test Temperature
|
135.0 C
|
Speed
|
20 rpm
|
Spindle size
|
21 in
|
Torque
|
23.0 %
|
Viscosity reading #1 (A)
|
0.645 Pa-s
|
Viscosity reading #2 (B)
|
0.645 Pa-s
|
Viscosity reading #3 (C)
|
0.645 Pa-s
|
Average viscosity
|
0.645 Pa-s
|
DIME Test ID: 2021-03-24-20-2
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 04/05/2021
Date Tested: 03/24/2021
Submitted By Organization: Veleroo - Coolidge
Organization Address: 123 Abc Street,
Organization City: Coolidge
Organization State: AZ
Organization Zipcode: 88888
Organization Email: binderlab1@gmail.com
Organization Phone: (111) 111-1111
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Phase
|
Original binder
|
Test Plate Diameter
|
25 mm
|
Phase Angle (δ) (for the 10 cycles)
|
87.9 degree
|
Dynamic Shear, G*/sin(δ)
|
1.58 kPa
|
DIME Test ID: 2021-03-24-20-3
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 04/05/2021
Date Tested: 03/24/2021
Submitted By Organization: Veleroo - Coolidge
Organization Address: 123 Abc Street,
Organization City: Coolidge
Organization State: AZ
Organization Zipcode: 88888
Organization Email: binderlab1@gmail.com
Organization Phone: (111) 111-1111
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Phase
|
RTFO residue
|
Test Plate Diameter
|
25 mm
|
Phase Angle (δ) (for the 10 cycles)
|
85.0 degree
|
Dynamic Shear, G*/sin(δ)
|
4.42 kPa
|
DIME Test ID: 2021-03-24-20-4
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Verified Date: 04/05/2021
Date Tested: 03/24/2021
Submitted By Organization: Veleroo - Coolidge
Organization Address: 123 Abc Street,
Organization City: Coolidge
Organization State: AZ
Organization Zipcode: 88888
Organization Email: binderlab1@gmail.com
Organization Phone: (111) 111-1111
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Is mass change based on one or two containers?
|
Two
|
Average mass change
|
-0.256 percent
|
DIME Test ID: 2021-03-24-20-5
Test Method: AASHTO T313-19: Standard Method of Test for Determining the Flexural Creep Stiffness of Asphalt Binder Using the Bending Beam Rheometer (BBR)
Verified Date: 04/05/2021
Date Tested: 03/25/2021
Submitted By Organization: Veleroo - Coolidge
Organization Address: 123 Abc Street,
Organization City: Coolidge
Organization State: AZ
Organization Zipcode: 88888
Organization Email: binderlab1@gmail.com
Organization Phone: (111) 111-1111
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Time test started
|
no data HH:MM:SS
|
Flags issued by software during test
|
no data
|
Correlation coefficient (R²)
|
no data0
|
Regression coefficient a
|
no data
|
Regression coefficient b
|
no data
|
Regression coefficient c
|
no data
|
Load at time 0.0
|
0.0 mN
|
Deflection at time 0.0 s
|
0.000 µm
|
Load at time 0.5 s
|
0.0 mN
|
Deflection at time 0.5 s
|
0.000 µm
|
Load at 60.0 s
|
0.0 mN
|
Beam deflection 60.0 s
|
0.000 µm
|
Measured Stiffness Modulus 60.0 s
|
109.000 mPa
|
Estimated Stiffness Modulus 60.0 s
|
109.000 mPa
|
Difference between stiffness moduli 60.0 s
|
no data
|
Estimated m-value 60.0 s
|
0.370
|
DIME Test ID: 2021-03-24-20-6
Test Method: AASHTO T48-18: Standard Method of Test for Flash Point of Asphalt Binder by Cleveland Open Cup
Verified Date: 04/05/2021
Date Tested: 03/24/2021
Submitted By Organization: Veleroo - Coolidge
Organization Address: 123 Abc Street,
Organization City: Coolidge
Organization State: AZ
Organization Zipcode: 88888
Organization Email: binderlab1@gmail.com
Organization Phone: (111) 111-1111
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Units of measurement for Observed Flash Point (C or F) and Ambient barometric pressure (kP or mmHg)
|
Celsius and mmHg
|
Observed Flash Point
|
316 C
|
Ambient Barometric Pressure
|
28.4 mmHg
|
Cleveland Open-Cup Flash Point in Celsius
|
317 C
|