Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 99999 DEA: 0322222
QA Service Level:
DIST-CO-RTE-PM: 03-SAC,OMG-888,99,80-0.6-0.6
Work Description: THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location Description: THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Michael Maksimovich Structure Rep.: Unknown
DIME Sample ID: 2021-03-30-1
TL Number from the TL Form:
Sample Submitted By Organization: Veleroo - Coolidge
Sample Organization Contact: 111-111-1111
Type of Sample: Quality Control
Type of Material: Asphalt Binder
Sample Taken Date: 03/30/2021
Date that the sample was received by the laboratory/organization performing the testing: 03/30/2021
The quantity of what the sample constitutes: 2 of 2 cans
A brief description of the sample: Asphalt Binder Sample
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: San Joaquin Refinery
Performance Grade: PG 70-10
Modified: No
Lot number:
Sublot number:
Tank number:
Time of sample:
HMA Supplier:
Certified Asphalt Supplier: San Joaquin Refinery - Bakersfield CA
Multigrade:
Multigrade Type:
Asphalt Binder Mix Number:
DIME Test ID: 2021-03-30-1-1
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Verified Date: 03/30/2021
Date Tested: 03/30/2021
Submitted By Organization: Veleroo - Coolidge
Organization Address: 123 Abc Street,
Organization City: Coolidge
Organization State: AZ
Organization Zipcode: 88888
Organization Email: binderlab1@gmail.com
Organization Phone: (111) 111-1111
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Is mass change based on one or two containers?
|
Two
|
Average mass change
|
-0.214 percent
|
DIME Test ID: 2021-03-30-1-2
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 03/30/2021
Date Tested: 03/30/2021
Submitted By Organization: Veleroo - Coolidge
Organization Address: 123 Abc Street,
Organization City: Coolidge
Organization State: AZ
Organization Zipcode: 88888
Organization Email: binderlab1@gmail.com
Organization Phone: (111) 111-1111
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Phase
|
Original binder
|
Test Plate Diameter
|
25 mm
|
Phase Angle (δ) (for the 10 cycles)
|
48.5 degree
|
Dynamic Shear, G*/sin(δ)
|
1.36 kPa
|