Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 040J7104 Cty SOL Rte 80 PM 1.8/4.4 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Quang Tran |
Date Reported: |
04/22/2021 |
|
Address: |
TL Number: |
01 |
||
City: |
||||
Project Name: RAISE BRIDGE AND PLACE STRUCTURAL CONCRETE. |
||||
Prime Contractor: BROSAMER & WALL, INC. |
||||
Sample Taken Date: |
03/25/2021 |
Mix Design: |
Unknown |
|
Contractor: Unknown |
Location : SOLANO COUNTY IN VALLEJO AT VARIOUS LOCATIONS |
|||
Structure unique identifier: |
||||
Structure name: Approach Slab at Abutment 1 |
||||
Location of Pour: |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 5.97 | 27.99 | 150692 | 5383.0 | 1 |
2 | 5.96 | 27.9 | 152000 | 5448.0 | 1 |
DIME Test ID: 2021-03-25-7-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 5420
Age of specimen: 7 days
Certified By: Mike Mullins
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 5.96 | 27.9 | 189380 | 6788.0 | 1 |
2 | 5.96 | 27.9 | 180115 | 6456.0 | 1 |
DIME Test ID: 2021-03-25-7-2
Number of specimens: 2
Compressive strength (to nearest 10 psi): 6620
Age of specimen: 28 days
Certified By: Mike Mullins
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing