Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 44444 DEA: ASCP EFIS: ASCP
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for submitting Sample information for Asphalt Supplier Certification Program.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2021-01-21-32
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Informational
Type of Material: Asphalt Binder
Sample Taken Date: 01/21/2021
Date that the sample was received by the laboratory/organization performing the testing: 03/08/2021
The quantity of what the sample constitutes: 1 of 4 cans
A brief description of the sample: Asphalt Binder
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: WORLD OIL
Performance Grade: PG 70-10
Modified: No
Lot number:
Sublot number:
Tank number:
Time of sample:
HMA Supplier:
Certified Asphalt Supplier: Lunday Thagard Company-World Oil - South Gate CA
Multigrade:
Multigrade Type:
Asphalt Binder Mix Number:
DIME Test ID: 2021-01-21-32-1
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 03/29/2021
Date Tested: 02/24/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: MSCR Study ORIG
Test Result Compliance: not applicable
Additional Comments When Verified:
Phase
|
Original binder
|
Test Plate Diameter
|
25 mm
|
Test Gap
|
1 mm
|
Test Frequency
|
10.0 rad/s
|
Strain Amplitude
|
12.00 %
|
Stress Amplitude
|
0.133 kPa
|
Phase Angle (δ) (for the 10 cycles)
|
88.4 degree
|
Complex Modulus (G*) (for the 10 measurements)
|
1.111 kPa
|
Test Temperature (Specimen 1)
|
70.0 C
|
Dynamic Shear, G*/sin(δ)
|
1.11 kPa
|
DIME Test ID: 2021-01-21-32-2
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 03/29/2021
Date Tested: 02/24/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: MSCR Study ORIG
Test Result Compliance: not applicable
Additional Comments When Verified:
Phase
|
Original binder
|
Test Plate Diameter
|
25 mm
|
Test Gap
|
1 mm
|
Test Frequency
|
10.0 rad/s
|
Strain Amplitude
|
12.00 %
|
Stress Amplitude
|
0.132 kPa
|
Phase Angle (δ) (for the 10 cycles)
|
88.4 degree
|
Complex Modulus (G*) (for the 10 measurements)
|
1.099 kPa
|
Test Temperature (Specimen 1)
|
70.0 C
|
Dynamic Shear, G*/sin(δ)
|
1.10 kPa
|
DIME Test ID: 2021-01-21-32-3
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 03/29/2021
Date Tested: 02/24/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: MSCR Study ORIG
Test Result Compliance: not applicable
Additional Comments When Verified:
Phase
|
Original binder
|
Test Plate Diameter
|
25 mm
|
Test Gap
|
1 mm
|
Test Frequency
|
10.0 rad/s
|
Strain Amplitude
|
12.00 %
|
Stress Amplitude
|
0.133 kPa
|
Phase Angle (δ) (for the 10 cycles)
|
88.4 degree
|
Complex Modulus (G*) (for the 10 measurements)
|
1.112 kPa
|
Test Temperature (Specimen 1)
|
70.0 C
|
Dynamic Shear, G*/sin(δ)
|
1.11 kPa
|
DIME Test ID: 2021-01-21-32-4
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 03/29/2021
Date Tested: 02/24/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: MSCR Study RTFO
Test Result Compliance: not applicable
Additional Comments When Verified:
Phase
|
RTFO residue
|
Test Plate Diameter
|
25 mm
|
Test Gap
|
1 mm
|
Test Frequency
|
10.0 rad/s
|
Strain Amplitude
|
10.00 %
|
Stress Amplitude
|
0.281 kPa
|
Phase Angle (δ) (for the 10 cycles)
|
86.0 degree
|
Complex Modulus (G*) (for the 10 measurements)
|
2.811 kPa
|
Test Temperature (Specimen 1)
|
70.0 C
|
Dynamic Shear, G*/sin(δ)
|
2.82 kPa
|
DIME Test ID: 2021-01-21-32-5
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 03/29/2021
Date Tested: 02/24/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: MSCR Study RTFO
Test Result Compliance: not applicable
Additional Comments When Verified:
Phase
|
RTFO residue
|
Test Plate Diameter
|
25 mm
|
Test Gap
|
1 mm
|
Test Frequency
|
10.0 rad/s
|
Strain Amplitude
|
10.00 %
|
Stress Amplitude
|
0.288 kPa
|
Phase Angle (δ) (for the 10 cycles)
|
85.9 degree
|
Complex Modulus (G*) (for the 10 measurements)
|
2.883 kPa
|
Test Temperature (Specimen 1)
|
70.0 C
|
Dynamic Shear, G*/sin(δ)
|
2.89 kPa
|
DIME Test ID: 2021-01-21-32-6
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 03/29/2021
Date Tested: 02/24/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: MSCR Study RTFO
Test Result Compliance: not applicable
Additional Comments When Verified:
Phase
|
RTFO residue
|
Test Plate Diameter
|
25 mm
|
Test Gap
|
1 mm
|
Test Frequency
|
10.0 rad/s
|
Strain Amplitude
|
10.00 %
|
Stress Amplitude
|
0.319 kPa
|
Phase Angle (δ) (for the 10 cycles)
|
85.6 degree
|
Complex Modulus (G*) (for the 10 measurements)
|
3.187 kPa
|
Test Temperature (Specimen 1)
|
70.0 C
|
Dynamic Shear, G*/sin(δ)
|
3.20 kPa
|
DIME Test ID: 2021-01-21-32-7
Test Method: AASHTO T350-19: Multiple Stress Creep Recovery (MSCR) Test of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Multiple Stress Creep Recovery)
Verified Date: 03/29/2021
Date Tested: 02/24/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: MSCR Study
Test Result Compliance: not applicable
Additional Comments When Verified:
PG test temperature
|
70.0 C
|
Average percent recovery at 0.1 kPa
|
2.5100 %
|
Average percent recovery at 3.2 kPa
|
0.0000 %
|
Nonrecoverable creep compliance
|
2.9592
|
Nonrecoverable creep compliance
|
3.2756
|
Percent difference between nonrecoverable creep compliance at 0.1 kPa and 3.2 kPa
|
10.6900 %
|
DIME Test ID: 2021-01-21-32-8
Test Method: AASHTO T350-19: Multiple Stress Creep Recovery (MSCR) Test of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Multiple Stress Creep Recovery)
Verified Date: 03/29/2021
Date Tested: 02/24/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: MSCR Study
Test Result Compliance: not applicable
Additional Comments When Verified:
PG test temperature
|
70.0 C
|
Average percent recovery at 0.1 kPa
|
1.7000 %
|
Average percent recovery at 3.2 kPa
|
0.0000 %
|
Nonrecoverable creep compliance
|
3.2850
|
Nonrecoverable creep compliance
|
3.5818
|
Percent difference between nonrecoverable creep compliance at 0.1 kPa and 3.2 kPa
|
9.0300 %
|
DIME Test ID: 2021-01-21-32-9
Test Method: AASHTO T350-19: Multiple Stress Creep Recovery (MSCR) Test of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Multiple Stress Creep Recovery)
Verified Date: 03/29/2021
Date Tested: 02/24/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: MSCR Study
Test Result Compliance: not applicable
Additional Comments When Verified:
PG test temperature
|
70.0 C
|
Average percent recovery at 0.1 kPa
|
2.5700 %
|
Average percent recovery at 3.2 kPa
|
0.0000 %
|
Nonrecoverable creep compliance
|
3.0843
|
Nonrecoverable creep compliance
|
3.4264
|
Percent difference between nonrecoverable creep compliance at 0.1 kPa and 3.2 kPa
|
11.0900 %
|