Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 66667 DEA: JMFPP EFIS: 0019000043
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for submitting Sample information for JMF Prequalification Program.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2021-01-10-5
TL Number from the TL Form:
Sample Submitted By Organization: Syar Industries, Incorporated
Sample Organization Contact: (707) 259-5705
Type of Sample: Preliminary
Type of Material: Hot Mix Asphalt
Sample Taken Date: 01/10/2021
Date that the sample was received by the laboratory/organization performing the testing: 01/10/2021
The quantity of what the sample constitutes: 780 Pounds
A brief description of the sample: 3/4" HMA-SP WMA
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Syar Todd Road Batch
DIME Test ID: 2021-01-10-5-1
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 03/18/2021
Date Tested: 01/10/2021
Submitted By Organization: Syar Industries, Incorporated
Organization Address: P.O. Box 2540,
Organization City: Napa
Organization State: CA
Organization Zipcode: 94558
Organization Email: nhall@syar.com
Organization Phone: (707) 333-8911
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of tests
|
1
|
What is the unit of measurement for theoretical density?
|
US Units
|
Mass Determination
|
Air
|
Specific Gravity for Sample 1
|
2.482
|
Theoretical maximum density at 25°C (77°F)
|
no data
|
DIME Test ID: 2021-01-10-5-2
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 03/18/2021
Date Tested: 01/10/2021
Submitted By Organization: Syar Industries, Incorporated
Organization Address: P.O. Box 2540,
Organization City: Napa
Organization State: CA
Organization Zipcode: 94558
Organization Email: nhall@syar.com
Organization Phone: (707) 333-8911
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Percent Air Voids
|
4.0 %
|
Percent Air Voids 2
|
3.9 %
|
Percent Air Voids 3
|
4.1 %
|
Percent Air Voids Average
|
4.0 %
|
DIME Test ID: 2021-01-10-5-3
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 03/18/2021
Date Tested: 01/10/2021
Submitted By Organization: Syar Industries, Incorporated
Organization Address: P.O. Box 2540,
Organization City: Napa
Organization State: CA
Organization Zipcode: 94558
Organization Email: nhall@syar.com
Organization Phone: (707) 333-8911
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Bulk Specific Gravity
|
2.382
|
Bulk Specific Gravity 2
|
2.385
|
Bulk Specific Gravity 3
|
2.380
|
Average Bulk Specific Gravity
|
2.382
|
DIME Test ID: 2021-01-10-5-4
Test Method: AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)
Verified Date: 03/18/2021
Date Tested: 01/10/2021
Submitted By Organization: Syar Industries, Incorporated
Organization Address: P.O. Box 2540,
Organization City: Napa
Organization State: CA
Organization Zipcode: 94558
Organization Email: nhall@syar.com
Organization Phone: (707) 333-8911
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel A)
|
25000
|
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel B)
|
25000
|
Impression at specified number of passes, or specified maximum impression if applicable (Wheel A)
|
0 mm
|
Impression at specified number of passes, or specified maximum impression if applicable (Wheel B)
|
0 mm
|
Stripping Inflection Point (Wheel A)
|
0
|
Stripping Inflection Point (Wheel B)
|
0
|