The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 6.00 | 28.27 | 188651 | 6672.0 | 1 |
2 | 6.00 | 28.27 | 193046 | 6828.0 | 1 |
3 | 6.00 | 28.27 | 186224 | 6586 | 1 |
4 | 6.00 | 28.27 | 187530 | 6633 | 1 |
DIME Test ID: 2021-03-05-11-1
Number of specimens: 4
Compressive strength (to nearest 10 psi): 6680
Age of specimen: 28 days