Sample Record for 2021-02-19-11
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 213856 DEA: 112888U4 EFIS: 1118000199
QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-11,125,905-Various
Work Description: CONSTRUCT FREEWAY TO FREEWAY CONNECTORS AND 4-LANE HIGHWAY FACILITY
Location Description: SAN DIEGO COUNTY AT VARIOUS LOCATIONS
Contractor Name: Skanska USA Civil West CA
Contractor Address: 1995 Agua Mansa Road, Riverside, CA 92509
Resident Engineer: Carlos Covarrubias Structure Rep.: Wade Durant
Sample Information
DIME Sample ID: 2021-02-19-11
TL Number from the TL Form: na
Sample Submitted By Organization: CT HQ - QASI Bay Area Field Office
Sample Organization Contact: (916) 284-6784
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 02/19/2021
Date that the sample was received by the laboratory/organization performing the testing: 02/19/2021
The quantity of what the sample constitutes: 2290
A brief description of the sample: Heavy Hex Bolt HDG
From where was the sample collected: Fabricator
Laboratory sample identification: na
Structure unique identifier:
Structure name: na
The fabricator/manufacturer/facility name: Universal Industrial Sales Inc
Material Information
Rocap Number(s): na
Heat Number(s): C20703050
Nut Mfg. Lot Number(s): na
Washer Mfg. Lot Number(s): na
Bolt Specification: A449, A153, F2329
Bolt Length(s): 1 1/4"
Nut Specification: na
Washer Specification: na
Finish: HDG
Diameter/Size: 3/8"
Bolt Mfg. Lot Number: 105296
Rocap Test Requirement(s): na
Lubricant Requirements(s): na
Test Results
Test 1 of 13
DIME Test ID: 2021-02-19-11-6
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/16/2021
Date Tested: 03/16/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
105296
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
BBC A449
|
Size
|
.375 in
|
Bolt Length
|
1.25 in
|
Measurement Average
|
2.46 mils
|
Test 2 of 13
DIME Test ID: 2021-02-19-11-7
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/16/2021
Date Tested: 03/16/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
105296
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
BBC A449
|
Size
|
.375 in
|
Bolt Length
|
1.25 in
|
Measurement Average
|
2.48 mils
|
Test 3 of 13
DIME Test ID: 2021-02-19-11-8
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/16/2021
Date Tested: 03/16/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
105296
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
BBC A449
|
Size
|
.375 in
|
Bolt Length
|
1.25 in
|
Measurement Average
|
2.42 mils
|
Test 4 of 13
DIME Test ID: 2021-02-19-11-9
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/16/2021
Date Tested: 03/16/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1D
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
105296
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
BBC A449
|
Size
|
.375 in
|
Bolt Length
|
1.25 in
|
Measurement Average
|
2.51 mils
|
Test 5 of 13
DIME Test ID: 2021-02-19-11-10
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/16/2021
Date Tested: 03/16/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1E
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
105296
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
BBC A449
|
Size
|
.375 in
|
Bolt Length
|
1.25 in
|
Measurement Average
|
2.82 mils
|
Test 6 of 13
DIME Test ID: 2021-02-19-11-11
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 03/16/2021
Date Tested: 03/16/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
105296
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
BBC A449
|
Size
|
.375 in
|
Bolt Length
|
1.25 in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
32.77
|
Spacing
|
Ok
|
Test 7 of 13
DIME Test ID: 2021-02-19-11-12
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 03/16/2021
Date Tested: 03/16/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
105296
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
BBC A449
|
Size
|
.375 in
|
Bolt Length
|
1.25 in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
31.22
|
Spacing
|
Ok
|
Test 8 of 13
DIME Test ID: 2021-02-19-11-13
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 03/16/2021
Date Tested: 03/16/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
105296
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
BBC A449
|
Size
|
.375 in
|
Bolt Length
|
1.25 in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
30.97
|
Spacing
|
Ok
|
Test 9 of 13
DIME Test ID: 2021-02-19-11-14
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 03/16/2021
Date Tested: 03/16/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
105296
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
BBC A449
|
Size
|
.375 in
|
Bolt Length
|
1.25 in
|
Pitch Diameter
|
.342 in
|
Pitch Diameter 2nd
|
.342 in
|
Test 10 of 13
DIME Test ID: 2021-02-19-11-15
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 03/16/2021
Date Tested: 03/16/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
105296
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
BBC A449
|
Size
|
.375 in
|
Bolt Length
|
1.25 in
|
Pitch Diameter
|
.336 in
|
Pitch Diameter 2nd
|
.336 in
|
Test 11 of 13
DIME Test ID: 2021-02-19-11-16
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 03/16/2021
Date Tested: 03/16/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
105296
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
BBC A449
|
Size
|
.375 in
|
Bolt Length
|
1.25 in
|
Pitch Diameter
|
.344 in
|
Pitch Diameter 2nd
|
.344 in
|
Test 12 of 13
DIME Test ID: 2021-02-19-11-17
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 03/16/2021
Date Tested: 03/16/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1D
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
105296
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
BBC A449
|
Size
|
.375 in
|
Bolt Length
|
1.25 in
|
Pitch Diameter
|
.341 in
|
Pitch Diameter 2nd
|
.341 in
|
Test 13 of 13
DIME Test ID: 2021-02-19-11-18
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 03/16/2021
Date Tested: 03/16/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1E
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
105296
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
BBC A449
|
Size
|
.375 in
|
Bolt Length
|
1.25 in
|
Pitch Diameter
|
.345 in
|
Pitch Diameter 2nd
|
.345 in
|