Project ID: 214579 DEA: 010B0904 EFIS: 0100020444
QA Service Level: 1
DIST-CO-RTE-PM: 01-DN-101-8.2/8.7
Work Description: Panther Creek & Hunter Creek Bridges
Location Description: DEL NORTE COUNTY NEAR KLAMATH AT PANTHER CREEK BRIDGE AND AT HUNTER CREEK BRIDGE
Contractor Name: Golden State Bridge, Inc
Contractor Address: 3701 Mallard Dr., Benicia, CA 94510
Resident Engineer: Ryan Dunne Structure Rep.: Brian Cinkutis
DIME Sample ID: 2021-01-13-31
TL Number from the TL Form:
Sample Submitted By Organization: Golden State Bridge, Incorporated
Sample Organization Contact: (415) 720-6577
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 01/13/2021
Date that the sample was received by the laboratory/organization performing the testing: 01/15/2021
The quantity of what the sample constitutes: 23 CY
A brief description of the sample: Structure Concrete
From where was the sample collected: Job Site
Laboratory sample identification: C7620A-D
Structure unique identifier:
Structure name: Panther Creek Temp Bridge
The fabricator/manufacturer/facility name: Tidewater Contractors
The concrete mix design number: 3-4_CIDH-TEMP
The truck number from where the sample was collected: 55954
The batch plant ticket number from where the sample was collected: 109
Concrete batch plant: Tidewater Contractor
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Abutment no. 2 - Right Pile
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2021-01-13-31-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 02/18/2021
Date Tested: 02/10/2021
Submitted By Organization: Golden State Bridge, Incorporated
Organization Address: 3701 Mallard Drive ,
Organization City: Benicia
Organization State: CA
Organization Zipcode: 94510
Organization Email: paul@gsbridge.com
Organization Phone: (415) 720-6577
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
2
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C617/CTM521
|
Average diameter of cylinder 1
|
6.00 in
|
Average diameter of cylinder 2
|
6.00 in
|
Cross sectional area of cylinder 1
|
28.27 in^2
|
Cross sectional area of cylinder 2
|
28.27 in^2
|
Compressive strength (to nearest 10 psi)
|
6920 psi
|
Maximum load on cylinder 1
|
191640 lb
|
Maximum load on cylinder 2
|
199420 lb
|
Type of fracture pattern of cylinder 1
|
2
|
Type of fracture pattern of cylinder 2
|
3
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
Samples C7620B & C7620C
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Age of specimen
|
27 days
|
Age of specimen in hours
|
no data
|