Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 66667 DEA: JMFPP EFIS: 0019000043
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for submitting Sample information for JMF Prequalification Program.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2020-01-17-22
TL Number from the TL Form:
Sample Submitted By Organization: Granite Construction Company - Coastal
Sample Organization Contact: (408) 327-7057
Type of Sample: Quality Control
Type of Material: Reclaimed Asphalt Pavement
Sample Taken Date: 01/17/2020
Date that the sample was received by the laboratory/organization performing the testing: 01/17/2020
The quantity of what the sample constitutes: multiple bags of RAP
A brief description of the sample: LP-9 Sample for ignition, sample 3
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Salinas Asphalt Facility
RAP Source: Salinas RAP, Continuous
Aggregate Size:
Aggregate Source:
RAP Stockpile:
Stockpile Size (tons):
Reclaimed Asphalt Pavement Mix Number:
DIME Test ID: 2020-01-17-22-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 02/11/2021
Date Tested: 11/26/2019
Submitted By Organization: Granite Construction Company - Coastal
Organization Address: 715 Comstock Street,
Organization City: Santa Clara, CA 95054
Organization State: CA
Organization Zipcode: 95054
Organization Email: hongbin.xie@gcinc.com
Organization Phone: 1 (408) 327-7057
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
What temperature unit is used?
|
Fahrenheit
|
Test procedure used?
|
Method A
|
Mass of HMA Sample prior to ignition
|
no data
|
Corrected Asphalt Binder Content
|
3.88 %
|
Mass Loss
|
no data
|
Correction Factor (Percent by mass of HMA Specimen)
|
no data
|
Moisture Content
|
no data
|
Temperature Compensation Factor
|
no data
|
Test Temperature
|
no data
|
DIME Test ID: 2020-01-17-22-2
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 02/11/2021
Date Tested: 11/26/2019
Submitted By Organization: Granite Construction Company - Coastal
Organization Address: 715 Comstock Street,
Organization City: Santa Clara, CA 95054
Organization State: CA
Organization Zipcode: 95054
Organization Email: hongbin.xie@gcinc.com
Organization Phone: 1 (408) 327-7057
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Is an aggregate correction factor used?
|
No
|
Cumulative percent passing the 2 in. sieve
|
100 %
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
Cumulative percent passing the 3/4 in. sieve
|
100 %
|
Cumulative percent passing the 1/2 in. sieve
|
99.2 %
|
Cumulative percent passing the 3/8 in. sieve
|
91.5 %
|
Cumulative percent passing the #4 sieve
|
68.1 %
|
Cumulative percent passing the #8 sieve
|
51.2 %
|
Cumulative percent passing the #16 sieve
|
38.4 %
|
Cumulative percent passing the #30 sieve
|
28.1 %
|
Cumulative percent passing the #50 sieve
|
19.1 %
|
Cumulative percent passing the #100 sieve
|
12.1 %
|
Cumulative percent passing the #200 sieve
|
7.6 %
|