Print Report | Back to Sample Detail

Sample Record for 2021-02-09-12

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215014 DEA: 101C9404 EFIS: 1016000020 QA Service Level: 1
DIST-CO-RTE-PM: 10-SJ-5-26.4/27.0
Work Description: BRIDGE REHABILITATION
Location Description: ON STATE HIGHWAY IN SAN JOAQUIN COUNTY IN STOCKTON FROM 0.3 MILE NORTH OF ROUTE 5/4 SEPARATION TO PERSHING AVENUE
Contractor Name: GOLDEN STATE BRIDGE, INC.
Contractor Address: 3701 Mallard Drive, Benicia, CA 94510
Resident Engineer: Chris Hanson Structure Rep.: Ron Matin

Sample Information

DIME Sample ID: 2021-02-09-12
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Sacramento Field Office
Sample Organization Contact: (916) 2058871
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 02/09/2021
Date that the sample was received by the laboratory/organization performing the testing: 02/12/2021
The quantity of what the sample constitutes: 87
A brief description of the sample: 5/8" x 7" Heavy Hex Bolt F1554
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CK Johnson

Material Information

Rocap Number(s):
Heat Number(s): 3093332
Nut Mfg. Lot Number(s):
Washer Mfg. Lot Number(s):
Bolt Specification: ASTM F1554
Bolt Length(s): 7"
Nut Specification: N/A
Washer Specification: N/A
Finish: HDG F2329
Diameter/Size: 5/8"
Bolt Mfg. Lot Number: 3093332
Rocap Test Requirement(s):
Lubricant Requirements(s):

Test Results

Test 1 of 7

DIME Test ID: 2021-02-09-12-4
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 03/08/2021
Date Tested: 02/26/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 3093332
Finish Coating ASTM F2329 - Hot Dip
Product Markings PB AB105
Size .625 in
Bolt Length 7 in
Gage Type Pass

Test 2 of 7

DIME Test ID: 2021-02-09-12-5
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 03/08/2021
Date Tested: 02/26/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 3093332
Finish Coating ASTM F2329 - Hot Dip
Product Markings PB AB105
Size .625 in
Bolt Length 7 in
Gage Type Pass

Test 3 of 7

DIME Test ID: 2021-02-09-12-6
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 03/08/2021
Date Tested: 02/26/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 3093332
Finish Coating ASTM F2329 - Hot Dip
Product Markings PB AB105
Size .625 in
Bolt Length 7 in
Gage Type Pass

Test 4 of 7

DIME Test ID: 2021-02-09-12-7
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/08/2021
Date Tested: 02/26/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 3093332
Finish Coating ASTM F2329 - Hot Dip
Product Markings PB AB105
Size .625 in
Bolt Length 7 in
Measurement Average 5.56 mils

Test 5 of 7

DIME Test ID: 2021-02-09-12-8
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/08/2021
Date Tested: 02/26/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 3093332
Finish Coating ASTM F2329 - Hot Dip
Product Markings PB AB105
Size .625 in
Bolt Length 7 in
Measurement Average 5.13 mils

Test 6 of 7

DIME Test ID: 2021-02-09-12-9
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/08/2021
Date Tested: 02/26/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 3093332
Finish Coating ASTM F2329 - Hot Dip
Product Markings PB AB105
Size .625 in
Bolt Length 7 in
Measurement Average 4.86 mils

Test 7 of 7

DIME Test ID: 2021-02-09-12-10
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 03/08/2021
Date Tested: 03/02/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: F1554 Gr105
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
1UNC 5/8 0.2263305414714625614258232224F1554 Gr105
UTM 400kip
Temperature 72