Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 215210 DEA: 030J1804 EFIS: 0319000232
QA Service Level: 1
DIST-CO-RTE-PM: 03-COL-5-6.8
Work Description: CONSTRUCT STRUCTURAL CONCRETE BARRIER SLAB AND CONCRETE BARRIER.
Location Description: COLUSA COUNTY AT HILLGATE ROAD UNDERCROSSING (BRIDGE NO. 15-0047)
Contractor Name: GORDON N BALL INC
Contractor Address: 333 CAMILLE AVENUE, ALAMO CA 94507
Resident Engineer: Garrett Griffith Structure Rep.: Unknown
DIME Sample ID: 2021-01-29-13
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 01/29/2021
Date that the sample was received by the laboratory/organization performing the testing: 02/04/2021
The quantity of what the sample constitutes: 3
A brief description of the sample: bearing pad
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Scougal Rubber
Mfg. Lot Number(s): 19588-1
Material/Compound/Elastomer ID: na
Samples Representing: 80
Description (size): 1"x4"x6"
Comments:
Description (Number of Shims): 0
Type of Bearing Pad: Plain
Description (Thickness of Shims): NA
Manufacturer(s): Scougal Rubber
Batch Number: na
DIME Test ID: 2021-01-29-13-1
Test Method: ASTM D2240-05re10: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 02/16/2021
Date Tested: 02/09/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature
|
72 f
|
Humidity
|
50 %
|
Reading #1
|
51
|
Reading #2
|
51
|
Reading #3
|
50
|
Reading #4
|
50
|
Reading #5
|
52
|
Mean
|
50.8
|
DIME Test ID: 2021-01-29-13-2
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 02/16/2021
Date Tested: 02/09/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested
|
3
|
Unit of the Ultimate Tensile Values
|
lbf per sqr in
|
UTM
|
2kip
|
Humidity
|
50.00 %
|
Temperature
|
72 F
|
Sample 1 Median Thickness
|
0.085
|
Sample 1 Thickness all Within 0.003 inch?
|
Yes
|
Sample 1 Ultimate Tensile
|
2581.89 lbf/in^2
|
Sample 1 Elongation (350% Min)
|
Pass
|
Sample 2 Median Thickness
|
0.083
|
Sample 2 Thickness all Within 0.003 inch?
|
Yes
|
Sample 2 Ultimate Tensile
|
2662.6 lbf/in^2
|
Sample 2 Elongation (350% Min)
|
Pass
|
Sample 3 Median Thickness
|
0.084
|
Sample 3 Thickness all Within 0.003 inch?
|
Yes
|
Sample 3 Ultimate Tensile
|
2621.95 lbf/in^2
|
Sample 3 Elongation (350% Min)
|
Pass
|
Median of the Ultimate Tensile Values
|
2622 lbf/in^2
|
DIME Test ID: 2021-01-29-13-3
Test Method: ASTM D624-00-re12: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Verified Date: 02/16/2021
Date Tested: 02/10/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested
|
3
|
UTM
|
2kip
|
Humidity
|
50.00 %
|
Temperature
|
72 F
|
Sample 1 Median Thickness
|
0.083
|
Sample 1 Tear Strength
|
237.2
|
Sample 2 Median Thickness
|
0.089
|
Sample 2 Tear Strength
|
285.6
|
Sample 3 Median Thickness
|
0.085
|
Sample 3 Tear Strength
|
248.6
|
Median of the Tear Strength Values
|
248.6 lb/in
|
DIME Test ID: 2021-01-29-13-4
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 02/11/2021
Date Tested: 02/11/2021
Submitted By Organization: CT HQ - Sacramento Chemistry Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: sanchita.dey@dot.ca.gov
Organization Phone: (916) 227-7912
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified: