Project ID: 99999 DEA: 0322222
QA Service Level:
DIST-CO-RTE-PM: 03-SAC,OMG-888,99,80-0.6-0.6
Work Description: THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location Description: THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Michael Maksimovich Structure Rep.: Unknown
DIME Sample ID: 2021-01-28-8
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Verification
Type of Material: Hot Mix Asphalt
Sample Taken Date: 01/28/2021
Date that the sample was received by the laboratory/organization performing the testing: 01/29/2021
The quantity of what the sample constitutes: 12 boxes
A brief description of the sample: 1/2" Type A HMA w 15% RAP
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Syar Industries Inc
DIME Test ID: 2021-01-28-8-1
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 01/29/2021
Date Tested: 01/29/2021
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of tests
|
1
|
What is the unit of measurement for theoretical density?
|
US Units
|
Mass Determination
|
Air
|
Method Performed
|
Mechanical Agitation - Method A
|
Mass of container filled with water
|
7358 grams
|
Mass of oven-dry sample in air for Sample 1
|
1342 grams
|
Mass of container filled with the sample and water for Sample 1
|
8157 grams
|
Temperature of Water
|
75 °F
|
Specific Gravity for Sample 1
|
2.468
|
Theoretical maximum density at 25°C (77°F)
|
no data
|
DIME Test ID: 2021-01-28-8-2
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 01/29/2021
Date Tested: 01/29/2021
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Percent Air Voids
|
4.5 %
|
Percent Air Voids 2
|
4.4
|
Percent Air Voids 3
|
3.9
|
Average Percent Air Voids
|
4.3
|
DIME Test ID: 2021-01-28-8-3
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 01/29/2021
Date Tested: 01/29/2021
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Bulk Specific Gravity
|
2.358
|
Bulk Specific Gravity 2
|
2.360
|
Bulk Specific Gravity 3
|
2.372
|
Average Bulk Specific Gravity
|
2.363
|
DIME Test ID: 2021-01-28-8-4
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 01/29/2021
Date Tested: 01/29/2021
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
What temperature unit is used?
|
Fahrenheit
|
Test procedure used?
|
Method A
|
Mass of the specimen basket assembly
|
no data
|
Mass of the specimen and specimen basket assembly prior to ignition
|
no data
|
Mass of HMA Sample prior to ignition
|
1,647.7 g
|
Corrected Asphalt Binder Content
|
5.76 %
|
Mass Loss
|
no data
|
Mass of aggregate remaining after ignition
|
1,519.9 g
|
Correction Factor (Percent by mass of HMA Specimen)
|
1.79 %
|
Moisture Content
|
0.21 %
|
Temperature Compensation Factor
|
no data
|
Test Temperature
|
no data
|