Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 041W6304 Cty SON Rte 12 PM 33.5-48.519.3 - 25.8, 33.5-48.519.3-25.8 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Paul Crawford |
Date Reported: |
02/08/2021 |
|
Address: |
TL Number: |
120793 |
||
City: |
||||
Project Name: Glass Fire-Fire damaged emergency repair project |
||||
Prime Contractor: TEAM GHILOTTI, INC |
||||
Sample Taken Date: |
01/11/2021 |
Mix Design: |
590CL2 |
|
Contractor: Unknown |
Location: |
|||
Structure unique identifier: |
||||
Structure name: |
||||
Location of Pour: |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 6.00 | 28.27 | 172050 | 6085.0 | 1 |
2 | 6.01 | 28.37 | 167770 | 5914.0 | 1 |
DIME Test ID: 2021-01-11-9-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 6000
Age of specimen: 28 days
Certified By: Mike Mullins
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing