DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 041W4804 Cty NAP Rte 121 PM 16.08/22.08, various, Various Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Danilo Patenia |
Date Reported: |
02/09/2021 |
|
Address: |
TL Number: |
193414 |
||
City: |
||||
Project Name: Fire damage |
||||
Prime Contractor: O.C. Jones |
||||
Sample Taken Date: |
01/12/2021 |
Mix Design: |
CT2530 |
|
Contractor: Unknown |
Location: Napa county, routes 121 and 128 |
|||
Structure unique identifier: |
||||
Structure name: |
||||
Location of Pour: |
The following testing has been tested in accordance with:
ASTM C39-10 : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Cross sectional area of cylinder (in^2) | Average diameter of cylinder (in) | Compressive strength of cylinder (psi) | Maximum load on cylinder (lb) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 27.99 | 5.97 | 5736.9 | 160576 | 1 |
2 | 27.81 | 5.95 | 5707.7 | 158731 | 1 |
DIME Test ID: 2021-01-12-11-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 5720
Comment on any defect in either specimen or caps (Max 250 Characters):
Age of specimen: 28 days
Certified By: Mike Mullins
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing