Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 66667 DEA: JMFPP EFIS: 0019000043
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for submitting Sample information for JMF Prequalification Program.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2020-12-28-17
TL Number from the TL Form:
Sample Submitted By Organization: Vulcan Materials Company - Pleasanton
Sample Organization Contact: (925) 260-3017
Type of Sample: Quality Control
Type of Material: Reclaimed Asphalt Pavement
Sample Taken Date: 12/28/2020
Date that the sample was received by the laboratory/organization performing the testing: 12/28/2020
The quantity of what the sample constitutes: 1
A brief description of the sample: RAP - Ign 2
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Materials - Pleasanton
DIME Test ID: 2020-12-28-17-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 12/28/2020
Date Tested: 12/28/2020
Submitted By Organization: Vulcan Materials Company - Pleasanton
Organization Address: 52 El Charro Road,
Organization City: Pleasanton
Organization State: CA
Organization Zipcode: 94588
Organization Email: ruedid@vmcmail.com
Organization Phone: (925) 260-3017
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
What temperature unit is used?
|
Fahrenheit
|
Test procedure used?
|
Method A
|
Mass of HMA Sample prior to ignition
|
no data
|
Corrected Asphalt Binder Content
|
6.35 %
|
Mass Loss
|
no data
|
Correction Factor (Percent by mass of HMA Specimen)
|
no data
|
Moisture Content
|
no data
|
Temperature Compensation Factor
|
no data
|
Test Temperature
|
no data
|
DIME Test ID: 2020-12-28-17-2
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 12/28/2020
Date Tested: 12/28/2020
Submitted By Organization: Vulcan Materials Company - Pleasanton
Organization Address: 52 El Charro Road,
Organization City: Pleasanton
Organization State: CA
Organization Zipcode: 94588
Organization Email: ruedid@vmcmail.com
Organization Phone: (925) 260-3017
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Is an aggregate correction factor used?
|
No
|
Cumulative percent passing the 2 in. sieve
|
100 %
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
Cumulative percent passing the 3/4 in. sieve
|
100 %
|
Cumulative percent passing the 1/2 in. sieve
|
100 %
|
Cumulative percent passing the 3/8 in. sieve
|
100 %
|
Cumulative percent passing the #4 sieve
|
82.9 %
|
Cumulative percent passing the #8 sieve
|
61.4 %
|
Cumulative percent passing the #16 sieve
|
44.3 %
|
Cumulative percent passing the #30 sieve
|
32.9 %
|
Cumulative percent passing the #50 sieve
|
23.9 %
|
Cumulative percent passing the #100 sieve
|
16.5 %
|
Cumulative percent passing the #200 sieve
|
11.8 %
|