Print Report | Back to Sample Detail

Sample Record for 2020-12-14-19

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214921 DEA: 09367404 EFIS: 0916000025 QA Service Level: 1
DIST-CO-RTE-PM: 09-KER-14-R4.7/R12.6
Work Description: CONSTRUCT CRCP OVER EXISTING PAVEMENT AND PLACE HMA.
Location Description: KERN COUNTY AT AND NEAR ROSAMOND AND MOJAVE FROM 1.4 MILES SOUTH OF DAWN ROAD OVERCROSSING TO 0.5 MILE NORTH OF SILVER QUEEN ROAD OVERCROSSING
Contractor Name: Jesus Pena
Contractor Address: 18201 Von Karman, Suite #800, IRVINE CA 92612
Resident Engineer: Hin Hartanto Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-12-14-19
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Acceptance
Type of Material: Aggregate
Sample Taken Date: 12/14/2020
Date that the sample was received by the laboratory/organization performing the testing: 12/23/2020
The quantity of what the sample constitutes: 1 Bag CF Agg., 1 Bag Virgin Agg., 1 Bag Rap
A brief description of the sample: 3/4" HMA-A-SP R25 0.8% Dry Lime
From where was the sample collected: Manufacturer
Laboratory sample identification: 0712A-20
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Granite Construction Littlerock

Material Information

Source Identification (SMARA, name of Pit or Job Site): 91-19-0046, 91-19-0008
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number: 13554
A detailed description of where the material sample was collected: Belt Cut at Granite Little Rock Plant
Where the material sample would have been placed if not sampled: Asphalt Paving
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number:

Test Results

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
2020-12-14-19-1AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)12/24/2020Not scheduledSatish JainCT D08 - Fontana Southern Regional Laboratory
2020-12-14-19-2AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)12/24/2020Not scheduledSatish JainCT D08 - Fontana Southern Regional Laboratory
2020-12-14-19-3CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates12/24/2020Not scheduledSatish JainCT D08 - Fontana Southern Regional Laboratory
2020-12-14-19-4CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates12/24/2020Not scheduledSatish JainCT D08 - Fontana Southern Regional Laboratory