Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 212112 DEA: 080C2514 EFIS: 0816000076 COOP: 081645
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-10-0.0/13.2
Work Description: Design-Build of I-10 Corridor Contract 1 - Adding 2 new Express Lanes
Location Description: LA/SBD County Line to PM 13.2 near I-15
Contractor Name: Lane-Security Paving Joint Venture
Contractor Address: 3450 Centre Lake Drive, 1st Floor, Ontario, CA 91761
Resident Engineer: Jose Corona Structure Rep.: Luis Negrete
DIME Sample ID: 2020-12-14-10
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 12/14/2020
Date that the sample was received by the laboratory/organization performing the testing: 12/15/2020
The quantity of what the sample constitutes: 25
A brief description of the sample: Bearing Pad
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Scougal Rubber
Mfg. Lot Number(s): 19414-6
Material/Compound/Elastomer ID: NA
Samples Representing: 1
Description (size): 4.03" x 12" x 26"
Comments:
Description (Number of Shims): 7
Type of Bearing Pad: Steel
Description (Thickness of Shims): 14 gage
Manufacturer(s): Scougal Rubber
Batch Number: NA
DIME Test ID: 2020-12-14-10-1
Test Method: ASTM D2240-05re10: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 01/11/2021
Date Tested: 01/06/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature
|
72 f
|
Humidity
|
50 %
|
Reading #1
|
52
|
Reading #2
|
52
|
Reading #3
|
51
|
Reading #4
|
53
|
Reading #5
|
51
|
Mean
|
51.8
|
DIME Test ID: 2020-12-14-10-2
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 01/11/2021
Date Tested: 01/07/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested
|
3
|
Unit of the Ultimate Tensile Values
|
lbf per sqr in
|
UTM
|
2kip
|
Humidity
|
50.00 %
|
Temperature
|
72 F
|
Sample 1 Median Thickness
|
0.079
|
Sample 1 Thickness all Within 0.003 inch?
|
Yes
|
Sample 1 Ultimate Tensile
|
2544.89 lbf/in^2
|
Sample 1 Elongation (350% Min)
|
Pass
|
Sample 2 Median Thickness
|
0.076
|
Sample 2 Thickness all Within 0.003 inch?
|
Yes
|
Sample 2 Ultimate Tensile
|
2720.97 lbf/in^2
|
Sample 2 Elongation (350% Min)
|
Pass
|
Sample 3 Median Thickness
|
0.078
|
Sample 3 Thickness all Within 0.003 inch?
|
Yes
|
Sample 3 Ultimate Tensile
|
2860.88 lbf/in^2
|
Sample 3 Elongation (350% Min)
|
Pass
|
Median of the Ultimate Tensile Values
|
2721 lbf/in^2
|
DIME Test ID: 2020-12-14-10-3
Test Method: ASTM D624-00-re12: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Verified Date: 01/11/2021
Date Tested: 01/07/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested
|
3
|
UTM
|
2kip
|
Humidity
|
50.00 %
|
Temperature
|
72 F
|
Sample 1 Median Thickness
|
0.083
|
Sample 1 Tear Strength
|
260
|
Sample 2 Median Thickness
|
0.076
|
Sample 2 Tear Strength
|
259
|
Sample 3 Median Thickness
|
0.074
|
Sample 3 Tear Strength
|
265.1
|
Median of the Tear Strength Values
|
260 lb/in
|
DIME Test ID: 2020-12-14-10-4
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 01/08/2021
Date Tested: 01/08/2021
Submitted By Organization: CT HQ - Sacramento Chemistry Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: sanchita.dey@dot.ca.gov
Organization Phone: (916) 227-7912
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified: