Print Report | Back to Sample Detail

Sample Record for 2020-11-10-13

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-11-10-13
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM10 - Wire Rope Choker
Sample Taken Date: 11/10/2020
Date that the sample was received by the laboratory/organization performing the testing: 12/14/2020
The quantity of what the sample constitutes: 2
A brief description of the sample: Wire Choker
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: District 11 Maitenance

Material Information

Reel Number: 650105
Painter Name or ID: Barreva Sigala
Material Specification: ASTM A931
Size: 5/16 in
Wire Manufacturer:
Material Collected to Test: Operator

Test Results

Test 1 of 2

DIME Test ID: 2020-11-10-13-1
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 12/15/2020
Date Tested: 12/15/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Wire Rope
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 F
UTM 67kip
Specimen Identification Wire Rope
Peak Load 10987.8
Operator Barreva
Location of Failure Below Crimp

Test 2 of 2

DIME Test ID: 2020-11-10-13-2
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 12/15/2020
Date Tested: 12/15/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Wire Rope Pull out of Crimp
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 F
UTM 67kip
Specimen Identification Wire Rope
Peak Load 10729.7
Operator Siglala
Location of Failure At Crimp