Print Report | Back to Sample Detail

Sample Record for 2020-11-10-13

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 88888 DEA: STOCK EFIS: STOCK QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-11-10-13
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Quality Assurance
Type of Material: SMTL TM10 - Wire Rope Choker
Sample Taken Date: 11/10/2020
Date that the sample was received by the laboratory/organization performing the testing: 12/14/2020
The quantity of what the sample constitutes: 2
A brief description of the sample: Wire Choker
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: District 11 Maitenance

Material Information

Reel Number: 650105
Painter Name or ID: Barreva Sigala
Material Specification: ASTM A931
Size: 5/16 in
Wire Manufacturer:
Material Collected to Test: Operator

Test Results

Test 1 of 2

DIME Test ID: 2020-11-10-13-1
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 12/15/2020
Date Tested: 12/15/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: Wire Rope
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 F
UTM 67kip
Specimen Identification Wire Rope
Peak Load 10987.8
Operator Barreva
Location of Failure Below Crimp

Test 2 of 2

DIME Test ID: 2020-11-10-13-2
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 12/15/2020
Date Tested: 12/15/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: Wire Rope Pull out of Crimp
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 F
UTM 67kip
Specimen Identification Wire Rope
Peak Load 10729.7
Operator Siglala
Location of Failure At Crimp

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
No tests have been assigned to this sample.