Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 030F2844 Cty SAC Rte 99 PM 7.1/9.4 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Masoud Saed |
Date Reported: |
12/29/2020 |
|
Address: |
TL Number: |
280570 |
||
City: |
||||
Project Name: Construct new PCC precast girder bridge over UPRR at McConnell OH between existing SB and NB alignments |
||||
Prime Contractor: GRANITE CONSTRUCTION COMPANY |
||||
Sample Taken Date: |
12/08/2020 |
Mix Design: |
545 |
|
Contractor: Unknown |
Location: |
|||
Structure unique identifier: |
||||
Structure name: |
||||
Location of Pour: |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 6.01 | 28.37 | 139929 | 4933.0 | 1 |
2 | 5.97 | 27.99 | 136589 | 4880.0 | 4 |
DIME Test ID: 2020-12-08-1-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 4910
Age of specimen: 14 days
Certified By: Mike Mullins
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 6.00 | 28.27 | 140569 | 4972.0 | 1 |
2 | 5.98 | 28.09 | 148649 | 5293.0 | 1 |
DIME Test ID: 2020-12-08-1-2
Number of specimens: 2
Compressive strength (to nearest 10 psi): 5130
Age of specimen: 21 days
Certified By: Mike Mullins
*Subject to final inspection by the Resident Engineer. |
![]() |
TL- Report of Laboratory Testing