Sample Record for 2020-11-18-20
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 214601 DEA: 041J5694 EFIS: 0419000313
QA Service Level: 1
DIST-CO-RTE-PM: 04-SM-101-0.0/21.8
Work Description: San Mateo US 101 Express Lanes North
Location Description:
Contractor Name: KIEWIT INFRASTRUCTURE COMPANY
Contractor Address: 1301 SHOREWAY RD, SUITE 275, BELMONT, CA 94402
Resident Engineer: Douglas Inori Structure Rep.: Tyler Pinell
Sample Information
DIME Sample ID: 2020-11-18-20
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 11/18/2020
Date that the sample was received by the laboratory/organization performing the testing: 11/24/2020
The quantity of what the sample constitutes: 28
A brief description of the sample: A325 Bolt Assemblies
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Nucor Unytite
Material Information
Rocap Number(s):
Heat Number(s): NF15103239 100201802 100201805 100898066 6213796404 NF15201353 DL19105173 75070238
Nut Mfg. Lot Number(s): 431190A 27724-75070238
Washer Mfg. Lot Number(s): 317500 D4382
Bolt Specification: A325
Bolt Length(s): 1.25" 2" 2.25" 2.5" 4" 4.25"
Nut Specification: A563
Washer Specification: F436
Finish: MG
Diameter/Size: .5" .75" 1.5"
Bolt Mfg. Lot Number: 368068A 430804A 430807A 427929B 21412-
Rocap Test Requirement(s):
Lubricant Requirements(s):
Test Results
Test 1 of 54
DIME Test ID: 2020-11-18-20-1
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Verified Date: 12/09/2020
Date Tested: 12/04/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A563
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By | 5A | 27724-75070238 | | 216692 | | A563 | fsaylor |
| |
UTM
|
450kip
|
Temperature
|
72 f
|
Test 2 of 54
DIME Test ID: 2020-11-18-20-2
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Verified Date: 12/09/2020
Date Tested: 12/04/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A563
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By | 2A | 431190A | | 52891 | | A563 | fsaylor |
| |
UTM
|
450kip
|
Temperature
|
72 f
|
Test 3 of 54
DIME Test ID: 2020-11-18-20-3
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 12/09/2020
Date Tested: 12/04/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A325
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples
|
1
|
Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By | 4A | 427929B | 0.7500 | 48374 | 215.18 | 10.00 | A325 | fsaylor |
| |
UTM
|
450kip
|
Temperature
|
no data
|
Test 4 of 54
DIME Test ID: 2020-11-18-20-4
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 12/09/2020
Date Tested: 12/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
368068A
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 N
|
Size
|
.5 in
|
Bolt Length
|
1.25 in
|
Gage Type
|
Pass
|
Test 5 of 54
DIME Test ID: 2020-11-18-20-5
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 12/09/2020
Date Tested: 12/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
2A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
430804A
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 USA N
|
Size
|
.75 in
|
Bolt Length
|
2 in
|
Gage Type
|
Pass
|
Test 6 of 54
DIME Test ID: 2020-11-18-20-6
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 12/09/2020
Date Tested: 12/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
3A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
430807A
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 USA N
|
Size
|
.75 in
|
Bolt Length
|
2.25 in
|
Gage Type
|
Pass
|
Test 7 of 54
DIME Test ID: 2020-11-18-20-7
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 12/09/2020
Date Tested: 12/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
3B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
430807A
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 USA N
|
Size
|
.75 in
|
Bolt Length
|
2.25 in
|
Gage Type
|
Pass
|
Test 8 of 54
DIME Test ID: 2020-11-18-20-8
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 12/09/2020
Date Tested: 12/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
3C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
430807A
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 USA N
|
Size
|
.75 in
|
Bolt Length
|
2.25 in
|
Gage Type
|
Pass
|
Test 9 of 54
DIME Test ID: 2020-11-18-20-9
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 12/09/2020
Date Tested: 12/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
4A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
427929B
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 USA N
|
Size
|
.75 in
|
Bolt Length
|
2.5 in
|
Gage Type
|
Pass
|
Test 10 of 54
DIME Test ID: 2020-11-18-20-10
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 12/09/2020
Date Tested: 12/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
5A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
21412-6213796404
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 USA
|
Size
|
1.5 in
|
Bolt Length
|
4 in
|
Gage Type
|
Pass
|
Test 11 of 54
DIME Test ID: 2020-11-18-20-11
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 12/09/2020
Date Tested: 12/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
6A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
21060-NF15201353
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 USA
|
Size
|
1.5 in
|
Bolt Length
|
4.25 in
|
Gage Type
|
Pass
|
Test 12 of 54
DIME Test ID: 2020-11-18-20-12
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 12/09/2020
Date Tested: 12/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
3A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
431190A
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
DH N
|
Size
|
.75 in
|
Gage Type
|
Pass
|
Test 13 of 54
DIME Test ID: 2020-11-18-20-13
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 12/09/2020
Date Tested: 12/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
3B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
431190A
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
DH N
|
Size
|
.75 in
|
Gage Type
|
Pass
|
Test 14 of 54
DIME Test ID: 2020-11-18-20-14
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 12/09/2020
Date Tested: 12/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
3C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
431190A
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
DH N
|
Size
|
.75 in
|
Gage Type
|
Pass
|
Test 15 of 54
DIME Test ID: 2020-11-18-20-15
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 12/09/2020
Date Tested: 12/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
5A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
27724-75070238
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
DH U
|
Size
|
1.5 in
|
Gage Type
|
Pass
|
Test 16 of 54
DIME Test ID: 2020-11-18-20-16
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 12/09/2020
Date Tested: 12/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
368068A
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 N
|
Size
|
.5 in
|
Bolt Length
|
1.25 in
|
Measurement Average
|
2.9 mils
|
Test 17 of 54
DIME Test ID: 2020-11-18-20-17
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 12/09/2020
Date Tested: 12/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
2A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
430804A
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 USA N
|
Size
|
.75 in
|
Bolt Length
|
2 in
|
Measurement Average
|
3.16 mils
|
Test 18 of 54
DIME Test ID: 2020-11-18-20-18
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 12/09/2020
Date Tested: 12/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
3A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
430807A
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 USA N
|
Size
|
.75 in
|
Bolt Length
|
2.25 in
|
Measurement Average
|
3.54 mils
|
Test 19 of 54
DIME Test ID: 2020-11-18-20-19
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 12/09/2020
Date Tested: 12/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
3B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
430807A
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 USA N
|
Size
|
.75 in
|
Bolt Length
|
2.25 in
|
Measurement Average
|
4.18 mils
|
Test 20 of 54
DIME Test ID: 2020-11-18-20-20
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 12/09/2020
Date Tested: 12/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
3C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
430807A
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 USA N
|
Size
|
.75 in
|
Bolt Length
|
2.25 in
|
Measurement Average
|
3.57 mils
|
Test 21 of 54
DIME Test ID: 2020-11-18-20-21
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 12/09/2020
Date Tested: 12/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
4A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
427929B
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 USA N
|
Size
|
.75 in
|
Bolt Length
|
2.5 in
|
Measurement Average
|
3.22 mils
|
Test 22 of 54
DIME Test ID: 2020-11-18-20-22
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 12/09/2020
Date Tested: 12/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
5A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
21412-6213796404
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 USA
|
Size
|
1.5 in
|
Bolt Length
|
4 in
|
Measurement Average
|
2.62 mils
|
Test 23 of 54
DIME Test ID: 2020-11-18-20-23
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 12/09/2020
Date Tested: 12/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
6A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
21060-NF15201353
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 USA
|
Size
|
1.5 in
|
Bolt Length
|
4.25 in
|
Measurement Average
|
4.11 mils
|
Test 24 of 54
DIME Test ID: 2020-11-18-20-24
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 12/09/2020
Date Tested: 12/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
2A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
431190A
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
DH N
|
Size
|
.75 in
|
Bolt Length
|
no data in
|
Measurement Average
|
4.06 mils
|
Test 25 of 54
DIME Test ID: 2020-11-18-20-25
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 12/09/2020
Date Tested: 12/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
3A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
431190A
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
DH N
|
Size
|
.75 in
|
Bolt Length
|
no data in
|
Measurement Average
|
4.1 mils
|
Test 26 of 54
DIME Test ID: 2020-11-18-20-26
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 12/09/2020
Date Tested: 12/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
3B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
431190A
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
DH N
|
Size
|
.75 in
|
Bolt Length
|
no data in
|
Measurement Average
|
3.98 mils
|
Test 27 of 54
DIME Test ID: 2020-11-18-20-27
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 12/09/2020
Date Tested: 12/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
5A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
27724-75070238
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
DH U
|
Size
|
1.5 in
|
Bolt Length
|
no data in
|
Measurement Average
|
3.25 mils
|
Test 28 of 54
DIME Test ID: 2020-11-18-20-28
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 12/09/2020
Date Tested: 12/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
2A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
317500
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
WS
|
Size
|
.75 in
|
Bolt Length
|
no data in
|
Measurement Average
|
2.74 mils
|
Test 29 of 54
DIME Test ID: 2020-11-18-20-29
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 12/09/2020
Date Tested: 12/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
3A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
317500
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
WS
|
Size
|
.75 in
|
Bolt Length
|
no data in
|
Measurement Average
|
2.44 mils
|
Test 30 of 54
DIME Test ID: 2020-11-18-20-30
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 12/09/2020
Date Tested: 12/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
3B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
317500
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
WS
|
Size
|
.75 in
|
Bolt Length
|
no data in
|
Measurement Average
|
2.39 mils
|
Test 31 of 54
DIME Test ID: 2020-11-18-20-31
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 12/09/2020
Date Tested: 12/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
5A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
D4382
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
F436 P
|
Size
|
1.5 in
|
Bolt Length
|
no data in
|
Measurement Average
|
2.47 mils
|
Test 32 of 54
DIME Test ID: 2020-11-18-20-32
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 12/09/2020
Date Tested: 12/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
368068A
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 N
|
Size
|
.5 in
|
Bolt Length
|
1.25 in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
29.2
|
Spacing
|
Ok
|
Test 33 of 54
DIME Test ID: 2020-11-18-20-33
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 12/09/2020
Date Tested: 12/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
2A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
430804A
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 USA N
|
Size
|
.75 in
|
Bolt Length
|
2 in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
29.82
|
Spacing
|
Ok
|
Test 34 of 54
DIME Test ID: 2020-11-18-20-34
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 12/09/2020
Date Tested: 12/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
3A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
430807A
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 USA N
|
Size
|
.75 in
|
Bolt Length
|
2.25 in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
28.37
|
Spacing
|
Ok
|
Test 35 of 54
DIME Test ID: 2020-11-18-20-35
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 12/09/2020
Date Tested: 12/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
5A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
21412-6213796404
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 USA
|
Size
|
1.5 in
|
Bolt Length
|
4 in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
23.15
|
Spacing
|
Ok
|
Test 36 of 54
DIME Test ID: 2020-11-18-20-36
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 12/09/2020
Date Tested: 12/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
6A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
21060-NF15201353
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 USA
|
Size
|
1.5 in
|
Bolt Length
|
4.25 in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
22.07
|
Spacing
|
Ok
|
Test 37 of 54
DIME Test ID: 2020-11-18-20-37
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 12/09/2020
Date Tested: 12/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
2A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
317500
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
WS
|
Size
|
.75 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
42.35
|
Spacing
|
Ok
|
Test 38 of 54
DIME Test ID: 2020-11-18-20-38
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 12/09/2020
Date Tested: 12/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
3A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
317500
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
WS
|
Size
|
.75 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
42.95
|
Spacing
|
Ok
|
Test 39 of 54
DIME Test ID: 2020-11-18-20-39
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 12/09/2020
Date Tested: 12/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
5A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
D4382
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
F436 P
|
Size
|
1.5 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
41.3
|
Spacing
|
Ok
|
Test 40 of 54
DIME Test ID: 2020-11-18-20-40
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 12/09/2020
Date Tested: 12/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
5B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
21412-6213796404
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 USA
|
Size
|
1.5 in
|
Bolt Length
|
4 in
|
Gage Type
|
Pass
|
Test 41 of 54
DIME Test ID: 2020-11-18-20-41
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 12/09/2020
Date Tested: 12/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
5C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
21412-6213796404
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 USA
|
Size
|
1.5 in
|
Bolt Length
|
4 in
|
Gage Type
|
Pass
|
Test 42 of 54
DIME Test ID: 2020-11-18-20-42
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 12/09/2020
Date Tested: 12/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
6B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
21060-NF15201353
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 USA
|
Size
|
1.5 in
|
Bolt Length
|
4.25 in
|
Gage Type
|
Pass
|
Test 43 of 54
DIME Test ID: 2020-11-18-20-43
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 12/09/2020
Date Tested: 12/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
6C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
21060-NF15201353
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 USA
|
Size
|
1.5 in
|
Bolt Length
|
4.25 in
|
Gage Type
|
Pass
|
Test 44 of 54
DIME Test ID: 2020-11-18-20-44
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 12/09/2020
Date Tested: 12/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
6D
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
21060-NF15201353
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 USA
|
Size
|
1.5 in
|
Bolt Length
|
4.25 in
|
Gage Type
|
Pass
|
Test 45 of 54
DIME Test ID: 2020-11-18-20-45
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 12/09/2020
Date Tested: 12/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
5B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
21412-6213796404
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 USA
|
Size
|
1.5 in
|
Bolt Length
|
4 in
|
Measurement Average
|
4.19 mils
|
Test 46 of 54
DIME Test ID: 2020-11-18-20-46
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 12/09/2020
Date Tested: 12/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
5C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
21412-6213796404
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 USA
|
Size
|
1.5 in
|
Bolt Length
|
4 in
|
Measurement Average
|
2.96 mils
|
Test 47 of 54
DIME Test ID: 2020-11-18-20-47
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 12/09/2020
Date Tested: 12/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
6B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
21060-NF15201353
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 USA
|
Size
|
1.5 in
|
Bolt Length
|
4.25 in
|
Measurement Average
|
6.06 mils
|
Test 48 of 54
DIME Test ID: 2020-11-18-20-48
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 12/09/2020
Date Tested: 12/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
6C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
21060-NF15201353
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 USA
|
Size
|
1.5 in
|
Bolt Length
|
4.25 in
|
Measurement Average
|
3.55 mils
|
Test 49 of 54
DIME Test ID: 2020-11-18-20-49
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 12/09/2020
Date Tested: 12/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
6D
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
21060-NF15201353
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 USA
|
Size
|
1.5 in
|
Bolt Length
|
4.25 in
|
Measurement Average
|
3.87 mils
|
Test 50 of 54
DIME Test ID: 2020-11-18-20-50
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 12/09/2020
Date Tested: 12/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
5B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
21412-6213796404
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 USA
|
Size
|
1.5 in
|
Bolt Length
|
4 in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
24.45
|
Spacing
|
Ok
|
Test 51 of 54
DIME Test ID: 2020-11-18-20-51
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 12/09/2020
Date Tested: 12/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
5C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
21412-6213796404
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 USA
|
Size
|
1.5 in
|
Bolt Length
|
4 in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
25.35
|
Spacing
|
Ok
|
Test 52 of 54
DIME Test ID: 2020-11-18-20-52
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 12/09/2020
Date Tested: 12/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
6B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
21060-NF15201353
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 USA
|
Size
|
1.5 in
|
Bolt Length
|
4.25 in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
24.48
|
Spacing
|
Ok
|
Test 53 of 54
DIME Test ID: 2020-11-18-20-53
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 12/09/2020
Date Tested: 12/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
6C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
21060-NF15201353
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 USA
|
Size
|
1.5 in
|
Bolt Length
|
4.25 in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
23.26
|
Spacing
|
Ok
|
Test 54 of 54
DIME Test ID: 2020-11-18-20-54
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 12/09/2020
Date Tested: 12/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
6D
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
21060-NF15201353
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 USA
|
Size
|
1.5 in
|
Bolt Length
|
4.25 in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
24
|
Spacing
|
Ok
|