Print Report | Back to Sample Detail

Sample Record for 2020-10-14-36

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215315 DEA: 081H8304 EFIS: 0817000139 QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD,SBD-138-0/2.3
Work Description: CONSTRUCT 4' MEDIAN
Location Description: SAN BERNARDINO COUNTY ALONG ROUTE 138
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 213 E Columbia Way, Lancaster, CA 93552
Resident Engineer: Mauricio Santa Cruz Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-10-14-36
TL Number from the TL Form: C002251
Sample Submitted By Organization: Wood
Sample Organization Contact: (916) 396-3815
Type of Sample: Per Request
Type of Material: Soil
Sample Taken Date: 10/14/2020
Date that the sample was received by the laboratory/organization performing the testing: 11/18/2020
The quantity of what the sample constitutes: 1 bag
A brief description of the sample: soil
From where was the sample collected: Job Site
Laboratory sample identification: CR20200515
Structure unique identifier: 08-SBD-138-PM 0.7
Structure name: Southbound
The fabricator/manufacturer/facility name: Caltrans

Material Information

The fabricator's/manufacturer's product name for the sample: A-20-002 - PM 0.7
The fabricator/manufacturer designation for the sample: Soil corrosion
A detailed description of where the material sample was collected: 5 feet depth
Where the material sample would have been placed if not sampled:

Test Results

Test 1 of 3

DIME Test ID: 2020-10-14-36-1
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Verified Date: 11/24/2020
Date Tested: 11/20/2020
Submitted By Organization: Wood
Organization Address: 9177 Sky Park Court,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92123
Organization Email: stephanie.antonucci@woodplc.com
Organization Phone: (916) 396-3815
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Minimum soil resistance corrected to 15.5 6307.00 Ohm-cm
Minimum soil resistivity at 15.5 6307 Ohm-cm
Minimum soil resistance of the lab measurement 5800 Ohms
Soil sample temperature 19 C
pH of soil 7.98

Test 2 of 3

DIME Test ID: 2020-10-14-36-2
Test Method: CTM 417-June 2014: Method of Testing Soils and Waters for Sulfate Content
Verified Date: 12/01/2020
Date Tested: 11/30/2020
Submitted By Organization: Wood
Organization Address: 9177 Sky Park Court,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92123
Organization Email: stephanie.antonucci@woodplc.com
Organization Phone: (916) 396-3815
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Material type Soils
Amount of the analyte in the sample 29

Test 3 of 3

DIME Test ID: 2020-10-14-36-3
Test Method: CTM 422-June 2014: Method of Testing Soils and Waters for Chloride Content
Verified Date: 12/01/2020
Date Tested: 11/30/2020
Submitted By Organization: Wood
Organization Address: 9177 Sky Park Court,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92123
Organization Email: stephanie.antonucci@woodplc.com
Organization Phone: (916) 396-3815
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Material type Soils
Amount of the analyte in the sample 22