Print Report | Back to Sample Detail

Sample Record for 2020-10-07-26

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215312 DEA: 034H5800 EFIS: 0318000336 QA Service Level: 2
DIST-CO-RTE-PM: 03-SAC-5-22.5/34.3
Work Description: I-5 Managed Lanes
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-10-07-26
TL Number from the TL Form: C021604A
Sample Submitted By Organization: Wood
Sample Organization Contact: (916) 396-3815
Type of Sample: Per Request
Type of Material: Soil
Sample Taken Date: 10/07/2020
Date that the sample was received by the laboratory/organization performing the testing: 11/18/2020
The quantity of what the sample constitutes: bag of soil
A brief description of the sample: Native soil
From where was the sample collected: Job Site
Laboratory sample identification: CR20200492
Structure unique identifier: 03-SAC-5-32.74
Structure name: Airport Blvd OC Retaining Wall and Abutment 1
The fabricator/manufacturer/facility name: Caltrans

Material Information

The fabricator's/manufacturer's product name for the sample: Soil RW-20-002
The fabricator/manufacturer designation for the sample: corrosion
A detailed description of where the material sample was collected: 21.5 - 25 feet depth
Where the material sample would have been placed if not sampled:

Test Results

Test 1 of 3

DIME Test ID: 2020-10-07-26-1
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Verified Date: 12/01/2020
Date Tested: 11/25/2020
Submitted By Organization: Wood
Organization Address: 9177 Sky Park Court,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92123
Organization Email: stephanie.antonucci@woodplc.com
Organization Phone: (916) 396-3815
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Minimum soil resistance corrected to 15.5 1271.00 Ohm-cm
Minimum soil resistivity at 15.5 1271 Ohm-cm
Minimum soil resistance of the lab measurement 1100 Ohms
Soil sample temperature 21.7 C
pH of soil 7.83

Test 2 of 3

DIME Test ID: 2020-10-07-26-2
Test Method: CTM 417-June 2014: Method of Testing Soils and Waters for Sulfate Content
Verified Date: 12/01/2020
Date Tested: 11/30/2020
Submitted By Organization: Wood
Organization Address: 9177 Sky Park Court,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92123
Organization Email: stephanie.antonucci@woodplc.com
Organization Phone: (916) 396-3815
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Material type Soils
Amount of the analyte in the sample 45

Test 3 of 3

DIME Test ID: 2020-10-07-26-3
Test Method: CTM 422-June 2014: Method of Testing Soils and Waters for Chloride Content
Verified Date: 12/01/2020
Date Tested: 11/30/2020
Submitted By Organization: Wood
Organization Address: 9177 Sky Park Court,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92123
Organization Email: stephanie.antonucci@woodplc.com
Organization Phone: (916) 396-3815
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Material type Soils
Amount of the analyte in the sample 55