Project Information

Project ID: 215312 DEA: 034H5800 EFIS: 0318000336 QA Service Level: 2
DIST-CO-RTE-PM: 03-SAC-5-22.5/34.3
Work Description: I-5 Managed Lanes
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-10-06-31
TL Number from the TL Form: C021603B
Sample Submitted By Organization: Wood
Sample Organization Contact: (916) 396-3815
Type of Sample: Per Request
Type of Material: Soil
Sample Taken Date: 10/06/2020
Date that the sample was received by the laboratory/organization performing the testing: 11/18/2020
The quantity of what the sample constitutes: bag of soil
A brief description of the sample: native soil
From where was the sample collected: Job Site
Laboratory sample identification: CR20200491
Structure unique identifier: 03-SAC-5-32.74
Structure name: Airport Blvd OC Retaining Wall and Abutment 3
The fabricator/manufacturer/facility name: Caltrans

Material Information

The fabricator's/manufacturer's product name for the sample: Soil RW-20-001
The fabricator/manufacturer designation for the sample: corrosion
A detailed description of where the material sample was collected: 30-31.5 feet depth
Where the material sample would have been placed if not sampled:

Test Results

Test 1 of 3

DIME Test ID: 2020-10-06-31-1
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Verified Date: 12/01/2020
Date Tested: 11/25/2020
Submitted By Organization: Wood
Organization Address: 9177 Sky Park Court,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92123
Organization Email: stephanie.antonucci@woodplc.com
Organization Phone: (916) 396-3815
General Comments for this Test:
Additional Comments When Verified:
Minimum soil resistance corrected to 15.5 1155.00 Ohm-cm
Minimum soil resistivity at 15.5 1155 Ohm-cm
Minimum soil resistance of the lab measurement 1000 Ohms
Soil sample temperature 21.7 C
pH of soil 7.98

Test 2 of 3

DIME Test ID: 2020-10-06-31-2
Test Method: CTM 417-June 2014: Method of Testing Soils and Waters for Sulfate Content
Verified Date: 12/01/2020
Date Tested: 11/30/2020
Submitted By Organization: Wood
Organization Address: 9177 Sky Park Court,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92123
Organization Email: stephanie.antonucci@woodplc.com
Organization Phone: (916) 396-3815
General Comments for this Test:
Additional Comments When Verified:
Material type Soils
Amount of the analyte in the sample 110

Test 3 of 3

DIME Test ID: 2020-10-06-31-3
Test Method: CTM 422-June 2014: Method of Testing Soils and Waters for Chloride Content
Verified Date: 12/01/2020
Date Tested: 11/30/2020
Submitted By Organization: Wood
Organization Address: 9177 Sky Park Court,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92123
Organization Email: stephanie.antonucci@woodplc.com
Organization Phone: (916) 396-3815
General Comments for this Test:
Additional Comments When Verified:
Material type Soils
Amount of the analyte in the sample 87

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
No tests have been assigned to this sample.