Print Report | Back to Sample Detail

Sample Record for 2020-11-09-21

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 213741 DEA: 07325704 EFIS: 0716000089 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-5-1.7
Work Description: BUILDING CONSTRUCTION IN LOS ANGELES COUNTY IN SANTA FE SPRINGS AT 14044 FREEWAY DRIVE.
Location Description: Santa Fe Springs, At 14044 Freeway Drive.
Contractor Name: AWI Builders Inc
Contractor Address: 7831 Paramount Bl, Pico Rivera Ca 90660
Resident Engineer: Mashhur Ali Structure Rep.: Nelson Parada

Sample Information

DIME Sample ID: 2020-11-09-21
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 11/09/2020
Date that the sample was received by the laboratory/organization performing the testing: 11/13/2020
The quantity of what the sample constitutes: 2
A brief description of the sample: A563 Nut & Washer
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Sputhwest Bolt Decker

Material Information

Rocap Number(s):
Heat Number(s):
Nut Mfg. Lot Number(s): 17-41-006
Washer Mfg. Lot Number(s): 0718-920
Bolt Specification: None
Bolt Length(s):
Nut Specification: A563
Washer Specification: F436
Finish: Plain
Diameter/Size: 1.0
Bolt Mfg. Lot Number:
Rocap Test Requirement(s):
Lubricant Requirements(s):

Test Results

Test 1 of 3

DIME Test ID: 2020-11-09-21-1
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Verified Date: 12/09/2020
Date Tested: 12/03/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Nut Striped
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
1A17-41-00699052Nut Stripedfsaylor
UTM 400kip
Temperature 72 f

Test 2 of 3

DIME Test ID: 2020-11-09-21-2
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 12/09/2020
Date Tested: 12/03/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 17-41-006
Finish Coating Plain
Product Markings D
Size 1 in
Gage Type Pass

Test 3 of 3

DIME Test ID: 2020-11-09-21-3
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 12/09/2020
Date Tested: 12/03/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 0718-920
Finish Coating Plain
Product Markings TSI F436
Size 1 in
Bolt Length no data in
Hardness Reading Scale C Scale
Hardness Reading Average 41.85
Spacing Ok