Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 214908 DEA: 112N0424 EFIS: 1118000193
QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-76-R4.2/R6.4
Work Description: PLACE MICROSURFACING, COLD PLANE AND REPLACE AC WITH HOT MIX ASPHALT.
Location Description: SAN DIEGO COUNTY IN OCEANSIDE FROM RANCHO DEL ORO DRIVE TO 0.2 MILE EAST OF COLLEGE BOULEVARD
Contractor Name: HAZARD CONSTRUCTION COMPANY
Contractor Address: 10529 Vine Streeet, Lakeside, CA 92040
Resident Engineer: Albert Labrador Structure Rep.: Unknown
DIME Sample ID: 2020-11-11-9
TL Number from the TL Form: Sacramento Caltrans lab
Sample Submitted By Organization: Kwik Bond Polymers
Sample Organization Contact: (760) 518-6064
Type of Sample: Quality Control
Type of Material: Polyester
Sample Taken Date: 11/11/2020
Date that the sample was received by the laboratory/organization performing the testing: 11/11/2020
The quantity of what the sample constitutes: 1 Tanker 16 Totes
A brief description of the sample: 1 gallon can
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Kwik Bond Polymers and Polynt
DIME Test ID: 2020-11-11-9-1
Test Method: ASTM D2196-Feb15: Standard Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational Viscometer
Verified Date: 12/04/2020
Date Tested: 12/04/2020
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joe.harline@dot.ca.gov
Organization Phone: (916) 206-4373
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
DIME Test ID: 2020-11-11-9-2
Test Method: ASTM D638-Dec14: Standard Test Method for Tensile Properties of Plastics
Verified Date: 12/04/2020
Date Tested: 12/04/2020
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joe.harline@dot.ca.gov
Organization Phone: (916) 206-4373
General Comments for this Test: Accepted supplier's results.
Test Result Compliance: complies
Additional Comments When Verified:
Number of specimens tested
|
5
|
Conditioning procedure
|
40/25/50
|
Speed of testing
|
0.45 in/min
|
Sample 1 Width
|
0.491 in
|
Sample 1 Ultimate strength
|
3736.4 psi
|
Sample 1 Thickness
|
0.146 in
|
Sample 1 Area
|
0.0717 in^2
|
Sample 1 Ultimate Strength Actual
|
267.9 lbs
|
Sample 1 percent elongation
|
66.7 %
|
Sample 1 Time
|
no data0 MM:SS
|
Sample 2 Width
|
0.49 in
|
Sample 2 Thickness
|
0.147 in
|
Sample 2 Area
|
0.072 in^2
|
Sample 2 Ultimate strength
|
3194.4 psi
|
Sample 2 Ultimate Strength Actual
|
230 lbs
|
Sample 2 percent elongation
|
53.6 %
|
Sample 2 Time
|
no data0 MM:SS
|
Sample 3 Width
|
0.49 in
|
Sample 3 Thickness
|
0.153 in
|
Sample 3 Area
|
0.075 in^2
|
Sample 3 Ultimate strength
|
3260 psi
|
Sample 3 Ultimate Strength Actual
|
244.5 lbs
|
Sample 3 percent elongation
|
56.6 %
|
Sample 3 Time
|
no data0 MM:SS
|
Sample 4 Width
|
0.493 in
|
Sample 4 Thickness
|
0.149 in
|
Sample 4 Area
|
0.0735 in^2
|
Sample 4 Ultimate strength
|
3163.3 psi
|
Sample 4 Ultimate Strength Actual
|
232.5 lbs
|
Sample 4 percent elongation
|
52.5 %
|
Sample 4 Time
|
no data0 MM:SS
|
Sample 5 Width
|
0.49 in
|
Sample 5 Thickness
|
0.138 in
|
Sample 5 Area
|
0.0676 in^2
|
Sample 5 Ultimate strength
|
3781.1 psi
|
Sample 5 Ultimate Strength Actual
|
255.6 lbs
|
Sample 5 percent elongation
|
64.2 %
|
Sample 5 Time
|
no data0 MM:SS
|
Ultimate Strength Average
|
3427 psi
|
Percent Elongation Average
|
59 %
|