Print Report | Back to Sample Detail

Sample Record for 2014-02-14-9303608

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 10016 DEA: 06342524 EFIS: 0600000381 QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE-180-R71.8/74.5
Work Description: NEW EXPRESS HIGHWAY
Location Description: FRESNO COUNTY ABOUT 6.3 MILES EAST OF FRESNO FROM 0.6 MILE WEST OF QUALITY AVENUE TO 0.2 MILE WEST OF SMITH AVENUE
Contractor Name: American Paving Co
Contractor Address: 315 North Thorne Avenue, Fresno, CA 93706
Resident Engineer: Mark Mengoni Structure Rep.: Mike Bloom

Sample Information

DIME Sample ID: 2014-02-14-9303608
TL Number from the TL Form:
Sample Submitted By Organization: Trinity Engineering Laboratories, Incorporated - Fresno
Sample Organization Contact: (559) 292-2188
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 02/14/2014
Date that the sample was received by the laboratory/organization performing the testing: 02/15/2014
The quantity of what the sample constitutes: 8 cylinders
A brief description of the sample: Type II Cement
From where was the sample collected: Other
Laboratory sample identification: 2014-02-14-002
Structure unique identifier: Hwy 180 at Fowler Switch Canal
Structure name: Hwy 180 at Fowler Switch Canal
The fabricator/manufacturer/facility name: Hwy 180 Mainling Bridge Deck

Material Information

The concrete mix design number: ND14505
The truck number from where the sample was collected: 9474
The batch plant ticket number from where the sample was collected: 114104582
Concrete batch plant: 114
The fabricator/manufacturer designation for the sample: Plant
A detailed description of where the material sample was collected: Hwy 180 at Fowler Switch Canal
Where the material sample would have been placed if not sampled: Hwt 180 at Fowler Switch Canal
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 8

DIME Test ID: 2014-02-14-9303608-1
Test Method: ASTM C143-10a: Standard Test Method for Slump of Hydraulic-Cement Concrete
Verified Date: 04/02/2014
Date Tested: 02/14/2014
Submitted By Organization: Trinity Engineering Laboratories, Incorporated - Fresno
Organization Address: 2473 North Sunnyside Avenue,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93727
Organization Email: mhorn@trinityeng.co
Organization Phone: (559) 260-6841
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Slump 4.75 inch

Test 2 of 8

DIME Test ID: 2014-02-14-9303608-2
Test Method: ASTM C138-10b: Standard Test Method for Density (Unit Weight), Yield, and Air Content (Gravimetric) of Concrete
Verified Date: 04/02/2014
Date Tested: 02/14/2014
Submitted By Organization: Trinity Engineering Laboratories, Incorporated - Fresno
Organization Address: 2473 North Sunnyside Avenue,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93727
Organization Email: mhorn@trinityeng.co
Organization Phone: (559) 260-6841
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Identification of concrete represented by the sample 2014-02-14-003-0930
Volume of the measure 0.25 ft^3
Density of concrete 148 lb/ft^3
Yield of concrete 9.28 yd^3
Relative yield of the batch 0.97
Cement content 7.18 lb/ft^3
Air content 1.6 %

Test 3 of 8

DIME Test ID: 2014-02-14-9303608-3
Test Method: ASTM C1064-08: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Verified Date: 04/02/2014
Date Tested: 02/14/2014
Submitted By Organization: Trinity Engineering Laboratories, Incorporated - Fresno
Organization Address: 2473 North Sunnyside Avenue,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93727
Organization Email: mhorn@trinityeng.co
Organization Phone: (559) 260-6841
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature 70 F

Test 4 of 8

DIME Test ID: 2014-02-14-9303608-4
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Verified Date: 04/02/2014
Date Tested: 02/21/2014
Submitted By Organization: Trinity Engineering Laboratories, Incorporated - Fresno
Organization Address: 2473 North Sunnyside Avenue,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93727
Organization Email: mhorn@trinityeng.co
Organization Phone: (559) 260-6841
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With density determined by dimension measurements
Average cylinder density (to nearest 1 pcf) 148.8 lb/ft^3
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Comment on any defect in either specimen or caps (Max 250 Characters) no data

Test 5 of 8

DIME Test ID: 2014-02-14-9303608-5
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Verified Date: 04/02/2014
Date Tested: 02/24/2014
Submitted By Organization: Trinity Engineering Laboratories, Incorporated - Fresno
Organization Address: 2473 North Sunnyside Avenue,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93727
Organization Email: mhorn@trinityeng.co
Organization Phone: (559) 260-6841
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 1
Test performed With density determined by dimension measurements
Density of cylinder 148.7 lb/ft^3
Average diameter of cylinder 1 6.00 in
Comment on any defect in either specimen or caps (Max 250 Characters) no data

Test 6 of 8

DIME Test ID: 2014-02-14-9303608-6
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Verified Date: 04/02/2014
Date Tested: 02/28/2014
Submitted By Organization: Trinity Engineering Laboratories, Incorporated - Fresno
Organization Address: 2473 North Sunnyside Avenue,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93727
Organization Email: mhorn@trinityeng.co
Organization Phone: (559) 260-6841
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 1
Test performed With density determined by dimension measurements
Density of cylinder 148.4 lb/ft^3
Average diameter of cylinder 1 6.00 in
Comment on any defect in either specimen or caps (Max 250 Characters) no data

Test 7 of 8

DIME Test ID: 2014-02-14-9303608-7
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Verified Date: 04/02/2014
Date Tested: 03/14/2014
Submitted By Organization: Trinity Engineering Laboratories, Incorporated - Fresno
Organization Address: 2473 North Sunnyside Avenue,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93727
Organization Email: mhorn@trinityeng.co
Organization Phone: (559) 260-6841
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With density determined by dimension measurements
Average cylinder density (to nearest 1 pcf) 147.9 lb/ft^3
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Comment on any defect in either specimen or caps (Max 250 Characters) no data

Test 8 of 8

DIME Test ID: 2014-02-14-9303608-8
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Verified Date: 04/02/2014
Date Tested: 03/29/2014
Submitted By Organization: Trinity Engineering Laboratories, Incorporated - Fresno
Organization Address: 2473 North Sunnyside Avenue,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93727
Organization Email: mhorn@trinityeng.co
Organization Phone: (559) 260-6841
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With density determined by dimension measurements
Average cylinder density (to nearest 1 pcf) 148.2 lb/ft^3
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Comment on any defect in either specimen or caps (Max 250 Characters) no data