Print Report | Back to Sample Detail

Sample Record for 2020-10-29-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 213700 DEA: 020H9004 EFIS: 0215000077 QA Service Level: 1
DIST-CO-RTE-PM: 02-BUT-70-41.9/42.3
Work Description: REMOVE CULVERTS AND CONSTRUCT BRIDGE
Location Description: BUTTE COUNTY NEAR PULGA FROM 2.5 MILES WEST OF PENSTOCK UNDERCROSSING TO 2.1 MILES WEST OF PENSTOCK UNDERCROSSING
Contractor Name: SHASTA SERVICES INC. DBA
Contractor Address: 509 S. Mt. Shasta Blvd., Mt. Shasta, CA 96067
Resident Engineer: John Yolton Structure Rep.: Adam Scardaci

Sample Information

DIME Sample ID: 2020-10-29-2
TL Number from the TL Form:
Sample Submitted By Organization: Con-Fab California, LLC
Sample Organization Contact: (661) 630-7162
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 10/29/2020
Date that the sample was received by the laboratory/organization performing the testing: 10/29/2020
The quantity of what the sample constitutes: 1 girder
A brief description of the sample: PCC 6"x12" test cylinder
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Con-Fab California, LLC

Material Information

The concrete mix design number: SCC-S98-25FA
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 2629
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Back of Truck
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 2

DIME Test ID: 2020-10-29-2-1
Test Method: CTM TEMP1-16: Test Method for Monitoring Precast Concrete Curing Temperature (Curing temperature)
Verified Date: 11/04/2020
Date Tested: 10/29/2020
Submitted By Organization: Con-Fab California, LLC
Organization Address: 701 Golds Avenue,
Organization City: Shafter
Organization State: CA
Organization Zipcode: 93263
Organization Email: trevorl@confabca.com
Organization Phone: (661) 630-3281
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Precast Maximum Curing Temperature 134 °F

Test 2 of 2

DIME Test ID: 2020-10-29-2-2
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 11/04/2020
Date Tested: 10/30/2020
Submitted By Organization: Con-Fab California, LLC
Organization Address: 701 Golds Avenue,
Organization City: Shafter
Organization State: CA
Organization Zipcode: 93263
Organization Email: trevorl@confabca.com
Organization Phone: (661) 630-3281
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Capped in accordance with? ASTM C1231
Cross sectional area of cylinder 1 28.27 in^2
Cross sectional area of cylinder 2 28.27 in^2
Compressive strength (to nearest 10 psi) 5190 psi
Maximum load on cylinder 1 147745 lb
Maximum load on cylinder 2 145490 lb
Type of fracture pattern of cylinder 1 2
Type of fracture pattern of cylinder 2 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 1 days
Age of specimen in hours 0 hours