Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 77777 DEA: CHEM-STOCK EFIS: CHEM-STOCK
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for Chem Lab stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2020-10-15-1
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 10/15/2020
Date that the sample was received by the laboratory/organization performing the testing: 10/19/2020
The quantity of what the sample constitutes: 5
A brief description of the sample: 3/4"-10x18"x4" ASTM F1554 Gr. 55 Anchor Bolt
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Blue Circle Corp
Rocap Number(s):
Heat Number(s): 3093312
Nut Mfg. Lot Number(s): 1-4
Washer Mfg. Lot Number(s):
Bolt Specification: ASTM F1554
Bolt Length(s): 18"x4"
Nut Specification: n/a
Washer Specification: n/a
Finish: HDG, ASTM F2329
Diameter/Size: 3/4"
Bolt Mfg. Lot Number: Lot 1-4
Rocap Test Requirement(s):
Lubricant Requirements(s):
DIME Test ID: 2020-10-15-1-1
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 10/21/2020
Date Tested: 10/20/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By | 1 | 3093312 | 0.498 | 0.195 | 73066 | 94545 | 25.9 | spaine |
| |
UTM
|
67kip
|
Temperature
|
72 f
|
DIME Test ID: 2020-10-15-1-2
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 10/21/2020
Date Tested: 10/20/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By | 2 | 3093312 | 0.498 | 0.195 | 73600 | 93956 | 26.2 | spaine |
| |
UTM
|
67kip
|
Temperature
|
72 f
|
DIME Test ID: 2020-10-15-1-3
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 10/21/2020
Date Tested: 10/20/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
3093312
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
YELLOW
|
Size
|
.75 in
|
Bolt Length
|
18 in
|
Gage Type
|
Pass
|
DIME Test ID: 2020-10-15-1-4
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 10/21/2020
Date Tested: 10/20/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
3093312
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
YELLOW
|
Size
|
.75 in
|
Bolt Length
|
18 in
|
Measurement Average
|
4.78 mils
|