Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 214731 DEA: 051M0004 EFIS: 0519000047
QA Service Level: 1
DIST-CO-RTE-PM: 05-SLO-101-16.5/R21.5
Work Description: COLD PLANE AND RHMA-GAP GRADED OVERLAY ON EXISTING ROADWAY.
Location Description: SAN LUIS OBISPO COUNTY IN AND NEAR PISMO BEACH FROM 0.1 MILE SOUTH OF PRICE CANYON ROAD TO SAN LUIS CREEK BRIDGE
Contractor Name: PAPICH CONSTRUCTION COMPANY, INC.
Contractor Address: 398 SUNRISE TERRACE, ARROYO GRANDE, CA 93425
Resident Engineer: Lilian Bennetzen Structure Rep.: Unknown
DIME Sample ID: 2020-09-30-9
TL Number from the TL Form:
Sample Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Sample Organization Contact: (559) 230-3109
Type of Sample: Department Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 09/30/2020
Date that the sample was received by the laboratory/organization performing the testing: 10/01/2020
The quantity of what the sample constitutes: 4 boxes
A brief description of the sample: 1/2" RHMA-G w/DL
From where was the sample collected: Manufacturer
Laboratory sample identification: 20-A-249
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Sierra Pacific Materials - Paso
DIME Test ID: 2020-09-30-9-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 10/02/2020
Date Tested: 10/02/2020
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used?
|
Fahrenheit
|
Test procedure used?
|
Method A
|
Mass of HMA Sample prior to ignition
|
no data
|
Corrected Asphalt Binder Content
|
7.01 %
|
Mass Loss
|
no data
|
Correction Factor (Percent by mass of HMA Specimen)
|
no data
|
Moisture Content
|
no data
|
Temperature Compensation Factor
|
no data
|
Test Temperature
|
no data
|
DIME Test ID: 2020-09-30-9-2
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 10/02/2020
Date Tested: 10/02/2020
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test:
Test Result Compliance: does not comply
Additional Comments When Verified:
What temperature unit is used?
|
Fahrenheit
|
Test procedure used?
|
Method A
|
Mass of HMA Sample prior to ignition
|
no data
|
Corrected Asphalt Binder Content
|
7.01 %
|
Mass Loss
|
no data
|
Correction Factor (Percent by mass of HMA Specimen)
|
no data
|
Moisture Content
|
no data
|
Temperature Compensation Factor
|
no data
|
Test Temperature
|
no data
|