Sample Record for 2013-12-16-11001792
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 7780 DEA: 112T1824 EFIS: 1100020051
QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-805-4.7/5.6
Work Description: REPLACE STRUCTURE AND CONSTRUCT DIRECT ACCESS RAMP (DAR).
Location Description: SAN DIEGO COUNTY IN CHULA VISTA FROM 0.4 MILE SOUTH OF EAST PALOMAR STREET OVERCROSSING TO 0.1 MILE NORTH OF NAPLES STREET UNDERCROSSING
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 5860 El Camino Real #200, Carlsbad, CA 92008
Resident Engineer: Tom Davis Structure Rep.: Anh Ma
Sample Information
DIME Sample ID: 2013-12-16-11001792
TL Number from the TL Form:
Sample Submitted By Organization: RMA Group - Rancho Cucamonga
Sample Organization Contact: (909) 989-1751
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 12/16/2013
Date that the sample was received by the laboratory/organization performing the testing:
The quantity of what the sample constitutes: 5 Cylinders
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Other
Laboratory sample identification: 2013-12-16-11-00
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Materials - Truck 336
Material Information
The concrete mix design number: 103612F
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 159113000000
Concrete batch plant: 41951
The fabricator/manufacturer designation for the sample: Vulcan Materials Company
A detailed description of where the material sample was collected: Retaining wall at bottom of wall Station 26.37
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
Test Results
Test 1 of 7
DIME Test ID: 2013-12-16-11001792-1
Test Method: ASTM C143-10a: Standard Test Method for Slump of Hydraulic-Cement Concrete
Verified Date: 02/03/2014
Date Tested: 12/16/2013
Submitted By Organization: RMA Group - Rancho Cucamonga
Organization Address: 12130 Santa Margarita Court,
Organization City: Rancho Cucamonga
Organization State: CA
Organization Zipcode: 91730
Organization Email: cbachler@rmacompanies.com
Organization Phone: (909) 989-1751
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Test 2 of 7
DIME Test ID: 2013-12-16-11001792-2
Test Method: ASTM C1064-08: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Verified Date: 02/03/2014
Date Tested: 12/16/2013
Submitted By Organization: RMA Group - Rancho Cucamonga
Organization Address: 12130 Santa Margarita Court,
Organization City: Rancho Cucamonga
Organization State: CA
Organization Zipcode: 91730
Organization Email: cbachler@rmacompanies.com
Organization Phone: (909) 989-1751
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Test 3 of 7
DIME Test ID: 2013-12-16-11001792-3
Test Method: ASTM C231-10: Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method
Verified Date: 02/03/2014
Date Tested: 12/16/2013
Submitted By Organization: RMA Group - Rancho Cucamonga
Organization Address: 12130 Santa Margarita Court,
Organization City: Rancho Cucamonga
Organization State: CA
Organization Zipcode: 91730
Organization Email: cbachler@rmacompanies.com
Organization Phone: (909) 989-1751
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Test 4 of 7
DIME Test ID: 2013-12-16-11001792-4
Test Method: ASTM C138-10b: Standard Test Method for Density (Unit Weight), Yield, and Air Content (Gravimetric) of Concrete
Verified Date: 02/03/2014
Date Tested: 12/16/2013
Submitted By Organization: RMA Group - Rancho Cucamonga
Organization Address: 12130 Santa Margarita Court,
Organization City: Rancho Cucamonga
Organization State: CA
Organization Zipcode: 91730
Organization Email: cbachler@rmacompanies.com
Organization Phone: (909) 989-1751
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Identification of concrete represented by the sample
|
Set 1
|
Volume of the measure
|
0.25 ft^3
|
Density of concrete
|
145.5 lb/ft^3
|
Yield of concrete
|
no data
|
Relative yield of the batch
|
no data
|
Cement content
|
no data
|
Air content
|
no data
|
Test 5 of 7
DIME Test ID: 2013-12-16-11001792-6
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521 Cured in accordance with ASTM C511
Verified Date: 02/03/2014
Date Tested: 12/23/2013
Submitted By Organization: Vulcan Materials Company - San Diego
Organization Address: 10051 Black Mountain Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92126
Organization Email: picenor@vmcmail.com
Organization Phone: 6195729564
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
2
|
Test performed
|
With no density determined
|
Cross sectional area of cylinder 1
|
no data
|
Cross sectional area of cylinder 2
|
no data
|
Capped in accordance with?
|
ASTM C617/CTM521
|
Compressive strength (to nearest 10 psi)
|
2850 psi
|
Average diameter of cylinder 1
|
6.00 in
|
Average diameter of cylinder 2
|
6.00 in
|
Maximum load on cylinder 1
|
79370 lb
|
Maximum load on cylinder 2
|
81550 lb
|
Type of fracture pattern of cylinder 1
|
3
|
Type of fracture pattern of cylinder 2
|
5
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
no data
|
Age of specimen
|
7 days
|
Test 6 of 7
DIME Test ID: 2013-12-16-11001792-7
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521 Cured in accordance with ASTM C511
Verified Date: 02/03/2014
Date Tested: 01/13/2014
Submitted By Organization: Vulcan Materials Company - San Diego
Organization Address: 10051 Black Mountain Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92126
Organization Email: picenor@vmcmail.com
Organization Phone: 6195729564
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
2
|
Test performed
|
With no density determined
|
Cross sectional area of cylinder 1
|
no data
|
Cross sectional area of cylinder 2
|
no data
|
Capped in accordance with?
|
ASTM C617/CTM521
|
Compressive strength (to nearest 10 psi)
|
4320 psi
|
Average diameter of cylinder 1
|
6.00 in
|
Average diameter of cylinder 2
|
6.00 in
|
Maximum load on cylinder 1
|
120890 lb
|
Maximum load on cylinder 2
|
123110 lb
|
Type of fracture pattern of cylinder 1
|
3
|
Type of fracture pattern of cylinder 2
|
6
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
no data
|
Age of specimen
|
28 days
|
Test 7 of 7
DIME Test ID: 2013-12-16-11001792-8
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521 Cured in accordance with ASTM C511
Verified Date: 05/01/2014
Date Tested: 02/10/2014
Submitted By Organization: Vulcan Materials Company - San Diego
Organization Address: 10051 Black Mountain Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92126
Organization Email: picenor@vmcmail.com
Organization Phone: 6195729564
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
1
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C617/CTM521
|
Compressive strength of cylinder (to nearest 10 psi)
|
5120 psi
|
Average diameter of cylinder 1
|
6.00 in
|
Maximum load on cylinder 1
|
144700 lb
|
Type of fracture pattern of cylinder 1
|
4
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Age of specimen
|
56 days
|