Print Report | Back to Sample Detail

Sample Record for 2020-09-29-4

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215113 DEA: 021J2404 EFIS: 0220000048 QA Service Level: 1
DIST-CO-RTE-PM: 02-SHA-273-
Work Description: PSPS Streetlight Backing plates-Steel Cantilever structure for solar panels
Location Description:
Contractor Name: CAL ELECTRO, INC.
Contractor Address: 3710 Electro Way, Redding, CA 96002
Resident Engineer: Michael Zdenek Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-09-29-4
TL Number from the TL Form:
Sample Submitted By Organization: CT QASI - Sacramento Field Laboratory
Sample Organization Contact: (916) 227-7263
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 09/29/2020
Date that the sample was received by the laboratory/organization performing the testing: 10/02/2020
The quantity of what the sample constitutes: 16
A brief description of the sample: F1554 Grade 36 HDG Anchor Bolts
From where was the sample collected: Distributor
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Portland Bolt

Material Information

Rocap Number(s):
Heat Number(s): 1202021930
Nut Mfg. Lot Number(s): NA
Washer Mfg. Lot Number(s): NA
Bolt Specification: ASTM F1554
Bolt Length(s): 48"
Nut Specification: NA
Washer Specification: NA
Finish: HDG
Diameter/Size: 1"
Bolt Mfg. Lot Number: 120202193061
Rocap Test Requirement(s): NA
Lubricant Requirements(s): NA

Test Results

Test 1 of 4

DIME Test ID: 2020-09-29-4-1
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 10/07/2020
Date Tested: 10/07/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Additional Comments When Verified:
Number of Samples 1
SampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
1106544600.5050.2572358055531.5spaine
UTM 67kip
Temperature 72 f

Test 2 of 4

DIME Test ID: 2020-09-29-4-2
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 10/07/2020
Date Tested: 10/07/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Additional Comments When Verified:
Number of Samples 1
SampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
2106544600.5030.199564118051830.9spaine
UTM 67kip
Temperature 72 f

Test 3 of 4

DIME Test ID: 2020-09-29-4-3
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 10/07/2020
Date Tested: 10/07/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) 1202021930
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings YELLOW PAINT
Size .75 in
Bolt Length 48 in
Gage Type Pass

Test 4 of 4

DIME Test ID: 2020-09-29-4-4
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 10/07/2020
Date Tested: 10/07/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) 1202021930
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings YELLOW PAINT
Size .75 in
Bolt Length 48 in
Measurement Average 2.49 mils

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
No tests have been assigned to this sample.