Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 214605 DEA: 051K7904 EFIS: 0519000026
QA Service Level: 1
DIST-CO-RTE-PM: 05-SB-166-R51.1/55.0
Work Description: COLD IN-PLACE RECYCLING AND RHMA OVERLAY.
Location Description: SANTA BARBARA COUNTY ABOUT 10 MILES WEST OF NEW CUYAMA FROM CUYAMA RIVER BRIDGE TO 3.1 MILES EAST OF COTTONWOOD CANYON ROAD
Contractor Name: Calportland Construction
Contractor Address: 1625 East Donovan Rd, Santa Maria, CA 93454
Resident Engineer: Thomas Petersen Structure Rep.: Unknown
DIME Sample ID: 2020-08-31-11
TL Number from the TL Form: 200831E
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Department Acceptance
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 08/31/2020
Date that the sample was received by the laboratory/organization performing the testing: 09/11/2020
The quantity of what the sample constitutes: 1can
A brief description of the sample: ARB #1 test, #2(200901E), #3(200902E), #4(200903E) No Test
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Cal Portland Garey Plant
Asphalt modifier supplier:
Performance Grade: PG 64-16
Lot number:
Sublot number:
Asphalt Rubber Binder Mix Number:
DIME Test ID: 2020-08-31-11-1
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Verified Date: 09/16/2020
Date Tested: 09/12/2020
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Determination
|
Worked Penetration
|
Worked Penetration
|
29 0.1 mm
|
DIME Test ID: 2020-08-31-11-2
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Verified Date: 09/16/2020
Date Tested: 09/15/2020
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
ASTM Thermometer used?
|
C
|
Softening Point Sample 1
|
70 C
|
Softening Point Sample 2
|
70 C
|
Bath Liquid
|
freshly boiled distilled water
|
Minutes Reaction
|
no data
|
DIME Test ID: 2020-08-31-11-3
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Verified Date: 09/16/2020
Date Tested: 09/15/2020
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature
|
25 C
|
Final Dial reading (F1)
|
79 mm
|
Ball Penetration (P1)
|
0 mm
|
Final Dial reading (F2)
|
79 mm
|
Ball Penetration (P2)
|
0 mm
|
Final Dial reading (F3)
|
80 mm
|
Ball Penetration (P3)
|
0 mm
|
Resilience 1
|
21 %
|
Resilience 2
|
21 %
|
Resilience 3
|
20 %
|
Average Resilience
|
21 %
|
Minutes Reaction
|
no data
|