Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 214601 DEA: 041J5694 EFIS: 0419000313
QA Service Level: 1
DIST-CO-RTE-PM: 04-SM-101-0.0/21.8
Work Description: San Mateo US 101 Express Lanes North
Location Description:
Contractor Name: KIEWIT INFRASTRUCTURE COMPANY
Contractor Address: 1301 SHOREWAY RD, SUITE 275, BELMONT, CA 94402
Resident Engineer: Douglas Inori Structure Rep.: Tyler Pinell
DIME Sample ID: 2020-07-30-33
TL Number from the TL Form:
Sample Submitted By Organization: Kiewit Infrastructure West Company - Redwood City
Sample Organization Contact: (619) 318-3509
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 07/30/2020
Date that the sample was received by the laboratory/organization performing the testing: 08/06/2020
The quantity of what the sample constitutes: 33 CY
A brief description of the sample: PCC Core
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name: Sign CIDH G-80
The fabricator/manufacturer/facility name: Central Concrete Supply
The concrete mix design number: DDLSP8Q3
The truck number from where the sample was collected: 1658
The batch plant ticket number from where the sample was collected: 18075868
Concrete batch plant: Central Concrete San Jose Plant
The fabricator/manufacturer designation for the sample: Unknown
A detailed description of where the material sample was collected: Sign G-80
Where the material sample would have been placed if not sampled: Sign CIDH
From Lot No.: Unknown
Bag Lot No.: Unknown
DIME Test ID: 2020-07-30-33-1
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 09/08/2020
Date Tested: 08/27/2020
Submitted By Organization: Kiewit Infrastructure West Company - Redwood City
Organization Address: 1301 Shoreway Road, Suite 275,
Organization City: Belmont
Organization State: CA
Organization Zipcode: 94002
Organization Email: daniel.geeslin@kiewit.com
Organization Phone: (619) 318-3509
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
2
|
Test performed
|
With no density determined
|
Average diameter of cylinder 1
|
6.00 in
|
Average diameter of cylinder 2
|
6.00 in
|
Capped in accordance with?
|
ASTM C617/CTM521
|
Cross sectional area of cylinder 1
|
28.27 in^2
|
Cross sectional area of cylinder 2
|
28.27 in^2
|
Compressive strength (to nearest 10 psi)
|
7510 psi
|
Maximum load on cylinder 1
|
209900 lb
|
Maximum load on cylinder 2
|
214790 lb
|
Type of fracture pattern of cylinder 1
|
5
|
Type of fracture pattern of cylinder 2
|
5
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Age of specimen
|
28 days
|
Age of specimen in hours
|
0 hours
|