Sample Record for 2020-08-30-3
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 213762 DEA: 032F3404 EFIS: 0300020616
QA Service Level: 1
DIST-CO-RTE-PM: 03-PLA-49-3.1/7.5
Work Description: WIDEN SHOULDERS, ADD RETAINING WALLS, REPLACE MBGR, CURBS & ELECTRICAL
Location Description: PLACER COUNTY IN AND NEAR AUBURN FROM 0.1 MILE SOUTH OF ROUTE 49/80 SEPARATION TO 0.1 MILE NORTH OF DRY CREEK ROAD
Contractor Name: FLATIRON WEST INC
Contractor Address: 2100 GOODYEAR ROAD, BENICIA, CA 94510
Resident Engineer: Jeff Johnson Structure Rep.: Unknown
Sample Information
DIME Sample ID: 2020-08-30-3
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Quality Assurance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 08/30/2020
Date that the sample was received by the laboratory/organization performing the testing: 09/04/2020
The quantity of what the sample constitutes: 1
A brief description of the sample: Bearing Pad
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Scougal Rubber
Material Information
Mfg. Lot Number(s): 19033-1R
Material/Compound/Elastomer ID: na
Samples Representing: 31
Description (size): 1.15"x9"x9"
Comments:
Description (Number of Shims): 2
Type of Bearing Pad: Steel
Description (Thickness of Shims): 14 gage
Manufacturer(s): Scougal Rubber
Batch Number: na
Test Results
Test 1 of 4
DIME Test ID: 2020-08-30-3-1
Test Method: ASTM D2240-05re10: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 09/10/2020
Date Tested: 09/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature
|
72 f
|
Humidity
|
50 %
|
Reading #1
|
51
|
Reading #2
|
52
|
Reading #3
|
51
|
Reading #4
|
50
|
Reading #5
|
50
|
Mean
|
50.8
|
Test 2 of 4
DIME Test ID: 2020-08-30-3-2
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 09/10/2020
Date Tested: 09/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested
|
3
|
Unit of the Ultimate Tensile Values
|
lbf per sqr in
|
UTM
|
2kip
|
Humidity
|
50.00 %
|
Temperature
|
72 F
|
Sample 1 Median Thickness
|
0.081
|
Sample 1 Thickness all Within 0.003 inch?
|
Yes
|
Sample 1 Ultimate Tensile
|
2710.99 lbf/in^2
|
Sample 1 Elongation (350% Min)
|
Pass
|
Sample 2 Median Thickness
|
0.076
|
Sample 2 Thickness all Within 0.003 inch?
|
Yes
|
Sample 2 Ultimate Tensile
|
2390.03 lbf/in^2
|
Sample 2 Elongation (350% Min)
|
Pass
|
Sample 3 Median Thickness
|
0.08
|
Sample 3 Thickness all Within 0.003 inch?
|
Yes
|
Sample 3 Ultimate Tensile
|
2736.13 lbf/in^2
|
Sample 3 Elongation (350% Min)
|
Pass
|
Median of the Ultimate Tensile Values
|
2711 lbf/in^2
|
Test 3 of 4
DIME Test ID: 2020-08-30-3-3
Test Method: ASTM D624-00-re12: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Verified Date: 09/10/2020
Date Tested: 09/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested
|
3
|
UTM
|
2kip
|
Humidity
|
50.00 %
|
Temperature
|
72 F
|
Sample 1 Median Thickness
|
0.083
|
Sample 1 Tear Strength
|
233.4
|
Sample 2 Median Thickness
|
0.076
|
Sample 2 Tear Strength
|
246.2
|
Sample 3 Median Thickness
|
0.081
|
Sample 3 Tear Strength
|
230.1
|
Median of the Tear Strength Values
|
233.4 lb/in
|
Test 4 of 4
DIME Test ID: 2020-08-30-3-4
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 09/09/2020
Date Tested: 09/09/2020
Submitted By Organization: CT HQ - Sacramento Chemistry Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: lisa.dobeck@dot.ca.gov
Organization Phone: (916) 227-7291
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified: