Print Report | Back to Sample Detail

Sample Record for 2020-08-14-26

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214876 DEA: 060W7604 EFIS: 0617000279 QA Service Level: 1
DIST-CO-RTE-PM: 06-KER,TUL-63,65,216-Var
Work Description: COLD PLANE ASPHALT CONCRETE PAVEMENT AND PLACE RHMA-G.
Location Description: KERN AND TULARE COUNTIES AT VARIOUS LOCATIONS
Contractor Name: Griffith Company
Contractor Address: 1128 Carrier Parkway, Bakersfield ,CA 93308
Resident Engineer: Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-08-14-26
TL Number from the TL Form: 865157
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Department Acceptance
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 08/14/2020
Date that the sample was received by the laboratory/organization performing the testing: 09/03/2020
The quantity of what the sample constitutes: 1 Can
A brief description of the sample: #1 test, No Test #2(865156), #3(865153),#4(865155)
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: deer creek asphalt

Material Information

Asphalt modifier supplier:
Performance Grade: PG 64-16
Lot number:
Sublot number:
Asphalt Rubber Binder Mix Number:

Test Results

Test 1 of 3

DIME Test ID: 2020-08-14-26-1
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Verified Date: 09/11/2020
Date Tested: 09/10/2020
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Determination Worked Penetration
Worked Penetration 34 0.1 mm

Test 2 of 3

DIME Test ID: 2020-08-14-26-2
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Verified Date: 09/11/2020
Date Tested: 09/10/2020
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature 25 C
Final Dial reading (F1) 76 mm
Ball Penetration (P1) no data0 mm
Final Dial reading (F2) 78 mm
Ball Penetration (P2) no data0 mm
Final Dial reading (F3) 76 mm
Ball Penetration (P3) 2 mm
Resilience 1 24 %
Resilience 2 22 %
Resilience 3 26 %
Average Resilience 24 %
Minutes Reaction no data

Test 3 of 3

DIME Test ID: 2020-08-14-26-3
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Verified Date: 09/11/2020
Date Tested: 09/10/2020
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
ASTM Thermometer used? C
Softening Point Sample 1 74 C
Softening Point Sample 2 74 C
Bath Liquid freshly boiled distilled water
Minutes Reaction no data