Sample Record for 2020-08-27-4
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 213741 DEA: 07325704 EFIS: 0716000089
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-5-1.7
Work Description: BUILDING CONSTRUCTION IN LOS ANGELES COUNTY IN SANTA FE SPRINGS AT 14044 FREEWAY DRIVE.
Location Description: Santa Fe Springs, At 14044 Freeway Drive.
Contractor Name: AWI Builders Inc
Contractor Address: 7831 Paramount Bl, Pico Rivera Ca 90660
Resident Engineer: Mashhur Ali Structure Rep.: Nelson Parada
Sample Information
DIME Sample ID: 2020-08-27-4
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 08/27/2020
Date that the sample was received by the laboratory/organization performing the testing: 08/31/2020
The quantity of what the sample constitutes: 40
A brief description of the sample: 1" x 3 1/4" TC Bolt assembly
From where was the sample collected: Distributor
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Bristol Machine
Material Information
Rocap Number(s):
Heat Number(s): Bolt 20628940
Nut 190841
Washer X4164
Nut Mfg. Lot Number(s): 31830-190841
Washer Mfg. Lot Number(s): D8640
Bolt Specification: ASTM F1852
Bolt Length(s): 3 1/4"
Nut Specification: ASTM A563 Gr. DH
Washer Specification: ASTM F436
Finish: Black
Diameter/Size: 5/8"
Bolt Mfg. Lot Number: 31657-20628940
Rocap Test Requirement(s):
Lubricant Requirements(s):
Test Results
Test 1 of 5
DIME Test ID: 2020-08-27-4-1
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 09/01/2020
Date Tested: 08/31/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A325 Wedge Tensile
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples
|
1
|
Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By | 1A | 31657-20628940 | 1.0000 | 95982 | 426.95 | 10.00 | A325 Wedge Tensile | spaine |
| |
UTM
|
450kip
|
Temperature
|
no data
|
Test 2 of 5
DIME Test ID: 2020-08-27-4-2
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Verified Date: 09/01/2020
Date Tested: 08/31/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Nut Proof Load
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By | 1A | 31830-190841 | | 110030 | | Nut Proof Load | spaine |
| |
UTM
|
450kip
|
Temperature
|
72 f
|
Test 3 of 5
DIME Test ID: 2020-08-27-4-3
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 09/01/2020
Date Tested: 09/01/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
31657-20628940
|
Finish Coating
|
Plain
|
Product Markings
|
A325TC USA
|
Size
|
1 in
|
Bolt Length
|
3.25 in
|
Gage Type
|
Pass
|
Test 4 of 5
DIME Test ID: 2020-08-27-4-4
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 09/01/2020
Date Tested: 09/01/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
31830-190841
|
Finish Coating
|
Plain
|
Product Markings
|
DH U
|
Size
|
1 in
|
Gage Type
|
Pass
|
Test 5 of 5
DIME Test ID: 2020-08-27-4-5
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 09/01/2020
Date Tested: 09/01/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
D8640
|
Finish Coating
|
Plain
|
Product Markings
|
F436 P
|
Size
|
1 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
41.25
|
Spacing
|
Ok
|