Print Report | Back to Sample Detail

Sample Record for 2020-08-14-25

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214802 DEA: 031G7004 EFIS: 0319000135 QA Service Level: 1
DIST-CO-RTE-PM: 03-SUT-99-28.0/30.6
Work Description: COLD PLANE AC PAVEMENT, RHMA OVERLAY, & INDUCTIVE LOOP DETECTORS.
Location Description: SUTTER COUNTY IN AND NEAR YUBA CITY FROM 0.1 MILE NORTH OF SMITH ROAD TO ROUTE 20
Contractor Name: DESILVA GATES CONSTRUCTION
Contractor Address: 3855 N Freeway Blvd. , Ste 105, Sacramento, CA 95834
Resident Engineer: Selvendran Manoharan Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-08-14-25
TL Number from the TL Form: C801769
Sample Submitted By Organization: CT HQ - Sacramento Aggregate Testing Laboratory
Sample Organization Contact: (916) 227-7204
Type of Sample: Acceptance
Type of Material: Aggregate
Sample Taken Date: 08/14/2020
Date that the sample was received by the laboratory/organization performing the testing: 08/20/2020
The quantity of what the sample constitutes: 1 bag
A brief description of the sample: 1/2" cold feed RHMA-O
From where was the sample collected: Source
Laboratory sample identification: 20-HMA-0166
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Desilva Gates-Marysville

Material Information

Source Identification (SMARA, name of Pit or Job Site): not provided
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Auto Sampler at sources
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 1/2 inch
The concrete mix design number:
Lot number: 1
Sublot number: 11
Aggregate Mix Number:

Test Results

Test 1 of 2

DIME Test ID: 2020-08-14-25-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 08/27/2020
Date Tested: 08/25/2020
Submitted By Organization: CT HQ - Sacramento Aggregate Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: bang.d.nguyen@dot.ca.gov
Organization Phone: (916) 227-7204
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
What type of gradation is being tested? HMA Gradation
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 96.1 %
Cumulative percent passing the 3/8 in. sieve 82.5 %
Cumulative percent passing the #4 sieve 33.8 %
Cumulative percent passing the #8 sieve 17.3 %
Cumulative percent passing the #16 sieve 10.6 %
Cumulative percent passing the #30 sieve 7.4 %
Cumulative percent passing the #50 sieve 5.5 %
Cumulative percent passing the #100 sieve 4.3 %
Cumulative percent passing the #200 sieve 3.39 %

Test 2 of 2

DIME Test ID: 2020-08-14-25-2
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Verified Date: 08/27/2020
Date Tested: 08/26/2020
Submitted By Organization: CT HQ - Sacramento Aggregate Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: bang.d.nguyen@dot.ca.gov
Organization Phone: (916) 227-7204
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sand Equivalent 77