Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2020-08-21-4
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Bay Area Field Office
Sample Organization Contact: (916) 284-6784
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 08/21/2020
Date that the sample was received by the laboratory/organization performing the testing: 08/21/2020
The quantity of what the sample constitutes: 7/83
A brief description of the sample: 7/8" x 18" A449 Heavy HEX Bolt
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: UIS Lindon UT
Rocap Number(s): No
Heat Number(s): 201157
Nut Mfg. Lot Number(s): N/A
Washer Mfg. Lot Number(s): N/A
Bolt Specification: ASTM A449
Bolt Length(s): 18"
Nut Specification: N/A
Washer Specification: N/A
Finish: HDG
Diameter/Size: 7/8"
Bolt Mfg. Lot Number: 33107-B
Rocap Test Requirement(s): No
Lubricant Requirements(s): No
DIME Test ID: 2020-08-21-4-1
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 09/02/2020
Date Tested: 08/27/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A449
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments | 4A | UNC 7/8 | 0.462 | 63955 | 284 | 138431 | 126550 | 58466 | A449 |
| |
UTM
|
400kip
|
Temperature
|
72
|
DIME Test ID: 2020-08-21-4-2
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 09/02/2020
Date Tested: 08/28/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
4A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
33107-B
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A449
|
Size
|
.875 in
|
Bolt Length
|
18 in
|
Gage Type
|
Pass
|
DIME Test ID: 2020-08-21-4-3
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 09/02/2020
Date Tested: 08/28/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
4B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
33107-B
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A449
|
Size
|
.875 in
|
Bolt Length
|
18 in
|
Gage Type
|
Pass
|
DIME Test ID: 2020-08-21-4-4
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 09/02/2020
Date Tested: 08/28/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
4C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
33107-B
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A449
|
Size
|
.875 in
|
Bolt Length
|
18 in
|
Gage Type
|
Pass
|
DIME Test ID: 2020-08-21-4-5
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 09/02/2020
Date Tested: 08/28/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
4A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
33107-B
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A449
|
Size
|
.875 in
|
Bolt Length
|
18 in
|
Measurement Average
|
2.84 mils
|
DIME Test ID: 2020-08-21-4-6
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 09/02/2020
Date Tested: 08/28/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
4B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
33107-B
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A449
|
Size
|
.875 in
|
Bolt Length
|
18 in
|
Measurement Average
|
2.63 mils
|
DIME Test ID: 2020-08-21-4-7
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 09/02/2020
Date Tested: 08/28/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
4C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
33107-B
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A449
|
Size
|
.875 in
|
Bolt Length
|
18 in
|
Measurement Average
|
2.8 mils
|