Print Report | Back to Sample Detail

Sample Record for 2020-07-23-38

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214465 DEA: 081E5704 EFIS: 0814000051 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-10-27.7
Work Description: PLACE CIDH PILING AND ROCK SLOPE PROTECTION
Location Description: RIVERSIDE COUNTY NEAR PALM SPRINGS AT WHITEWATER RIVER BRIDGE
Contractor Name: ROCKFORCE CONSTRUCTION, LLC
Contractor Address: 26771 Vista Terrace, Lake Forest, CA, 92630
Resident Engineer: Peter Koury Structure Rep.: Shukri Abouazra

Sample Information

DIME Sample ID: 2020-07-23-38
TL Number from the TL Form: 050961
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 07/23/2020
Date that the sample was received by the laboratory/organization performing the testing: 07/24/2020
The quantity of what the sample constitutes: 2 Cylinders
A brief description of the sample: Concrete Cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 1016-961
Structure unique identifier:
Structure name: Left Bridge Whitewater Bridge
The fabricator/manufacturer/facility name: NA

Material Information

The concrete mix design number: Not Provided on TL
The truck number from where the sample was collected: Not Provided on TL
The batch plant ticket number from where the sample was collected: Not Provided on TL
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Chute
Where the material sample would have been placed if not sampled: CIDH Pile Pier 7 East Left Bridge Whitewater Bridge
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2020-07-23-38-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 09/02/2020
Date Tested: 08/21/2020
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617/CTM521
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Cross sectional area of cylinder 1 28.27 in^2
Cross sectional area of cylinder 2 28.27 in^2
Compressive strength (to nearest 10 psi) 4720 psi
Maximum load on cylinder 1 132810 lb
Maximum load on cylinder 2 134100 lb
Compressive strength of cylinder 1 4697.9 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 4743.5 psi
Type of fracture pattern of cylinder 2 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 29 days
Age of specimen in hours no data