Print Report | Back to Sample Detail

Sample Record for 2020-07-27-30

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214756 DEA: 050N7AU4 EFIS: 0520000030 QA Service Level: 1
DIST-CO-RTE-PM: 05-SB-101-1.4/4.8
Work Description: Construct HOV lanes and rehabilitation
Location Description: CARPINTERIA FROM 0.2 MILE SOUTH OF BAILARD AVENUE OVERCROSSING TO 0.7 MILE SOUTH OF SOUTH PADARO LANE
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 5335 Debbie Rd, Santa Barbara, CA 93160
Resident Engineer: Taylor Merlo Structure Rep.: Barajas, Raymond A.

Sample Information

DIME Sample ID: 2020-07-27-30
TL Number from the TL Form:
Sample Submitted By Organization: CT D05 - Field Laboratory
Sample Organization Contact: (559) 230-3109
Type of Sample: Verification
Type of Material: Reclaimed Asphalt Pavement
Sample Taken Date: 07/27/2020
Date that the sample was received by the laboratory/organization performing the testing: 07/28/2020
The quantity of what the sample constitutes: One JMF Verification
A brief description of the sample: 25% Fine Fraction
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Granite Buellton

Material Information

RAP Source: Granite Gardner 3/8
Aggregate Size:
Aggregate Source:
RAP Stockpile:
Stockpile Size (tons):

Test Results

Test 1 of 3

DIME Test ID: 2020-07-27-30-1
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 08/13/2020
Date Tested: 08/11/2020
Submitted By Organization: CT D05 - Field Laboratory
Organization Address: 50 Higuera St,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: doug.lambert@dot.ca.gov
Organization Phone: (559) 230-3109
General Comments for this Test:
Additional Comments When Verified:
Does this test use 1/4 sieve? No
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 100 %
Cumulative percent passing the 3/8 in. sieve 98.3 %
Cumulative percent passing the #4 sieve 81.1 %
Cumulative percent passing the #8 sieve 64.8 %
Cumulative percent passing the #16 sieve 50.8 %
Cumulative percent passing the #30 sieve 39.2 %
Cumulative percent passing the #50 sieve 27.2 %
Cumulative percent passing the #100 sieve 16.8 %
Cumulative percent passing the #200 sieve 10.5 %

Test 2 of 3

DIME Test ID: 2020-07-27-30-2
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 08/13/2020
Date Tested: 07/24/2020
Submitted By Organization: CT D05 - Field Laboratory
Organization Address: 50 Higuera St,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: doug.lambert@dot.ca.gov
Organization Phone: (559) 230-3109
General Comments for this Test:
Additional Comments When Verified:
Number of tests 1
Mass Determination Air
Specific Gravity for Sample 1 2.426

Test 3 of 3

DIME Test ID: 2020-07-27-30-3
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Asphalt Binder Content)
Verified Date: 08/13/2020
Date Tested: 07/31/2020
Submitted By Organization: CT D05 - Field Laboratory
Organization Address: 50 Higuera St,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: doug.lambert@dot.ca.gov
Organization Phone: (559) 230-3109
General Comments for this Test:
Additional Comments When Verified:
Test procedure used? Method A
Asphalt Binder Content 7.07 %
Mass of HMA prior to ignition 1520.3 g
Mass of aggregate remaining after ignition 1412.8 g
Correction Factor (Percent by mass of HMA Specimen) no data
Moisture Content no data
Test Temperature 1000 F

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
No tests have been assigned to this sample.