Project ID: 8801 DEA: AML-CEM EFIS: AML-CEM
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for Cementitious Materials for use in Concrete Authorized Material List (AML)
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2020-07-20-22
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Sample Organization Contact: (916) 227-7071
Type of Sample: Acceptance
Type of Material: Cementitious
Sample Taken Date: 07/20/2020
Date that the sample was received by the laboratory/organization performing the testing: 07/20/2020
The quantity of what the sample constitutes: 1 Bucket
A brief description of the sample: Type II Cement
From where was the sample collected: Source
Laboratory sample identification: CM205076
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Lehigh
DIME Test ID: 2020-07-20-22-2
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Verified Date: 12/29/2020
Date Tested: 08/21/2020
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Will control cubes be used per ASTM C311?
|
no
|
Age of specimen
|
3 days
|
The amount of flow
|
110 %
|
The amount of water used
|
48.5 %
|
Compressive strength of 1st specimen
|
3444 psi
|
Compressive strength of 2nd specimen
|
3328 psi
|
Compressive strength of 3rd specimen
|
3301 psi
|
Average Compressive strength (to nearest 10 psi)
|
3360 psi
|
DIME Test ID: 2020-07-20-22-3
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Verified Date: 12/29/2020
Date Tested: 08/25/2020
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Will control cubes be used per ASTM C311?
|
no
|
Age of specimen
|
7 days
|
The amount of flow
|
no data %
|
The amount of water used
|
48.4 %
|
Compressive strength of 1st specimen
|
4503 psi
|
Compressive strength of 2nd specimen
|
4552 psi
|
Compressive strength of 3rd specimen
|
4682 psi
|
Average Compressive strength (to nearest 10 psi)
|
4580 psi
|
DIME Test ID: 2020-07-20-22-4
Test Method: ASTM C191-13: Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat Needle
Verified Date: 12/29/2020
Date Tested: 09/02/2020
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Type of Water Used
|
Potable
|
Initial time of setting
|
108 min
|
Final time of setting
|
no data
|
DIME Test ID: 2020-07-20-22-5
Test Method: ASTM C185-15a: Standard Test Method for Air Content of Hydraulic Cement Mortar
Verified Date: 12/29/2020
Date Tested: 09/02/2020
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Specific gravity
|
3.15
|
Water Content
|
246
|
The amount of flow (In percent)
|
89 %
|
The amount of water used (In percent)
|
70.29 %
|
Net Weight of Sample
|
830.3 grams
|
Air Content
|
8 %
|
DIME Test ID: 2020-07-20-22-6
Test Method: ASTM C204-11: Standard Test Methods for Fineness of Hydraulic Cement by Air-Permeability Apparatus
Verified Date: 12/29/2020
Date Tested: 09/02/2020
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Method Used
|
Test Method A
|
Test Time
|
96 seconds
|
Fineness
|
3955 cm^2/g
|