Project Information

Project ID: 214733 DEA: 060R1104 EFIS: 0614000030 QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE,KER-119,198-Var
Work Description: CULVERT REPLACEMENT.
Location Description: FRESNO AND KERN COUNTIES AT VARIOUS LOCATIONS.
Contractor Name: CCFG CONSTRUCTION
Contractor Address: 17750 Wards Ferry Road, Sonoma, CA, 95370
Resident Engineer: Robert Decker Structure Rep.: Evan Stensvad

Sample Information

DIME Sample ID: 2020-08-06-10
TL Number from the TL Form:
Sample Submitted By Organization: Forterra
Sample Organization Contact: 916-381-3910
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 08/06/2020
Date that the sample was received by the laboratory/organization performing the testing: 08/07/2020
The quantity of what the sample constitutes: 1 days production
A brief description of the sample: CONCRETE
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Forterra Pipe and Precast, Florin Rd

Material Information

The concrete mix design number: mix 5
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 001
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: conveyor belt
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2020-08-06-10-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 08/10/2020
Date Tested: 08/07/2020
Submitted By Organization: Forterra
Organization Address: 7020 Tokay Avenue,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95828
Organization Email: edgar.benitez@forterrabp.com
Organization Phone: 916-381-3910
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C1231
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Cross sectional area of cylinder 1 28.27 in^2
Cross sectional area of cylinder 2 28.27 in^2
Compressive strength (to nearest 10 psi) 2470 psi
Maximum load on cylinder 1 71435 lb
Maximum load on cylinder 2 67995 lb
Type of fracture pattern of cylinder 1 2
Type of fracture pattern of cylinder 2 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 1 days
Age of specimen in hours 24 hours

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
No tests have been assigned to this sample.