Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 214513 DEA: 021H3904 EFIS: 0216000041
QA Service Level: 1
DIST-CO-RTE-PM: 02-SHA-5-R32.0/R32.3
Work Description: O'BRIEN DECK AND RAIL REHAB: WEATHER INFO SYSTEM, STRUCTURAL CONCRETE, HMA, REMOVE BRIDGE BARRIER.
Location Description: SHASTA COUNTY ABOUT 10 MILES SOUTH OF LAKEHEAD FROM 0.1 MILE SOUTH TO 0.3 MILE NORTH OF O'BRIEN UNDERCROSSING
Contractor Name: Golden State Bridge
Contractor Address: 2990 Bay Vista Court, Benicia, CA 94510
Resident Engineer: Nathan Alexander Structure Rep.: George Moore
DIME Sample ID: 2020-06-02-32
TL Number from the TL Form: 036437
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Verification
Type of Material: Reclaimed Asphalt Pavement
Sample Taken Date: 06/02/2020
Date that the sample was received by the laboratory/organization performing the testing: 06/02/2020
The quantity of what the sample constitutes: JMF Verification Renewal
A brief description of the sample: Combined RAP (1/2-inch)
From where was the sample collected: Manufacturer
Laboratory sample identification: D78452B
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Northstate Asphalt, Redding, CA
DIME Test ID: 2020-06-02-32-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 08/03/2020
Date Tested: 06/04/2020
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used?
|
Fahrenheit
|
Test procedure used?
|
Method A
|
Mass of HMA Sample prior to ignition
|
1952.3 g
|
Corrected Asphalt Binder Content
|
5.75 %
|
Mass Loss
|
no data
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.00 %
|
Moisture Content
|
0.00 %
|
Temperature Compensation Factor
|
no data
|
Test Temperature
|
1000 F
|
DIME Test ID: 2020-06-02-32-2
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 08/03/2020
Date Tested: 06/05/2020
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Is an aggregate correction factor used?
|
No
|
Cumulative percent passing the 2 in. sieve
|
100 %
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
Cumulative percent passing the 3/4 in. sieve
|
98.9 %
|
Cumulative percent passing the 1/2 in. sieve
|
91.4 %
|
Cumulative percent passing the 3/8 in. sieve
|
80.5 %
|
Cumulative percent passing the 1/4 in. sieve
|
64.3 %
|
Cumulative percent passing the #4 sieve
|
56.5 %
|
Cumulative percent passing the #8 sieve
|
42.8 %
|
Cumulative percent passing the #16 sieve
|
31.8 %
|
Cumulative percent passing the #30 sieve
|
24 %
|
Cumulative percent passing the #50 sieve
|
17.7 %
|
Cumulative percent passing the #100 sieve
|
13 %
|
Cumulative percent passing the #200 sieve
|
9.8 %
|
DIME Test ID: 2020-06-02-32-3
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 08/03/2020
Date Tested: 06/04/2020
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of tests
|
1
|
What is the unit of measurement for theoretical density?
|
US Units
|
Mass Determination
|
Air
|
Method Performed
|
Mechanical Agitation - Method A
|
Mass of container filled with water
|
7338.0 grams
|
Mass of oven-dry sample in air for Sample 1
|
1531.0 grams
|
Mass of container filled with the sample and water for Sample 1
|
8263.0 grams
|
Temperature of Water
|
73 °F
|
Specific Gravity for Sample 1
|
2.526
|
Theoretical maximum density at 25°C (77°F)
|
no data
|