Project ID: 214385 DEA: 024G6104 EFIS: 0214000028
QA Service Level: 1
DIST-CO-RTE-PM: 02-SHA,TRI-3,299-VAR
Work Description: HMA, LIGHTING AND BRIDGE RAIL REPLACEMENT.
Location Description: SHASTA AND TRINITY COUNTIES AT VARIOUS LOCATIONS
Contractor Name: Tullis Inc
Contractor Address: 16951 Clear Creek Road, Redding, CA 96001
Resident Engineer: Mandhir Grewal Structure Rep.: Robert Thompson
DIME Sample ID: 2020-07-21-26
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Acceptance
Type of Material: Asphalt Binder
Sample Taken Date: 07/21/2020
Date that the sample was received by the laboratory/organization performing the testing: 07/30/2020
The quantity of what the sample constitutes: 9 each cans, #10 TEST (6-14)
A brief description of the sample: Asphalt Binder PG 58-34M
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Valero - Benicia
Performance Grade: PG 58-34 M
Modified: Yes
Lot number:
Sublot number:
Tank number:
Time of sample:
HMA Supplier:
Certified Asphalt Supplier:
Multigrade:
Multigrade Type:
Asphalt Binder Mix Number:
DIME Test ID: 2020-07-21-26-1
Test Method: AASHTO T301-13: Standard Method of Test for Elastic Recovery Test of Asphalt Materials by Means of a Ductilometer
Verified Date: 09/21/2020
Date Tested: 08/07/2020
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Final Reading from the testing machine (X)
|
5 cm
|
% Elongation Recovery
|
75 %
|
DIME Test ID: 2020-07-21-26-2
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Verified Date: 09/21/2020
Date Tested: 08/03/2020
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Is mass change based on one or two containers?
|
One
|
Any material loss from containers during heating process/testing?
|
No
|
Mass of empty container #1
|
169.600 grams
|
Mass of container #1 before test (m1i)
|
204.140 grams
|
Mass of container #1 after test (m1f)
|
203.830 grams
|
Average mass change
|
-0.898 percent
|
DIME Test ID: 2020-07-21-26-3
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 08/14/2020
Date Tested: 08/14/2020
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Phase
|
Original binder
|
Test Plate Diameter
|
25 mm
|
Phase Angle (δ) (for the 10 cycles)
|
67.4 degree
|
Dynamic Shear, G*/sin(δ)
|
2.61 kPa
|
DIME Test ID: 2020-07-21-26-4
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 09/02/2020
Date Tested: 09/01/2020
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: At 64 degrees Phase Angle = 63.8 degree and Dynamic Shear = 4.4932 kPa
Test Result Compliance:
Additional Comments When Verified:
Phase
|
RTFO residue
|
Test Plate Diameter
|
25 mm
|
Phase Angle (δ) (for the 10 cycles)
|
62.0 degree
|
Dynamic Shear, G*/sin(δ)
|
8.44 kPa
|
DIME Test ID: 2020-07-21-26-5
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 09/02/2020
Date Tested: 09/02/2020
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Phase
|
PAV residue
|
Test Plate Diameter
|
8 mm
|
Phase Angle (δ) (for the 10 cycles)
|
37.9 degree
|
(G*) x sin(δ)=
|
3012 kPa
|
DIME Test ID: 2020-07-21-26-6
Test Method: AASHTO T313-19: Standard Method of Test for Determining the Flexural Creep Stiffness of Asphalt Binder Using the Bending Beam Rheometer (BBR)
Verified Date: 09/21/2020
Date Tested: 09/09/2020
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Supplier M-value = 0.300, precision by multi-laboratory passed.
Test Result Compliance:
Additional Comments When Verified:
Minimum test bath temperature at 240 s
|
no data
|
Maximum test bath temperature at 240 s
|
no data
|
Time of test load application
|
no data HH:MM:SS
|
File name of test data
|
no data
|
Time beam in bath
|
no data
|
Time test started
|
no data HH:MM:SS
|
Flags issued by software during test
|
no data
|
Correlation coefficient (R²)
|
0
|
Regression coefficient a
|
no data
|
Regression coefficient b
|
no data
|
Regression coefficient c
|
no data
|
Load at time 0.0
|
0.0 mN
|
Deflection at time 0.0 s
|
0.000 µm
|
Load at time 0.5 s
|
0.0 mN
|
Deflection at time 0.5 s
|
0.000 µm
|
Load at 60.0 s
|
0.0 mN
|
Beam deflection 60.0 s
|
0.000 µm
|
Measured Stiffness Modulus 60.0 s
|
180.000 mPa
|
Estimated Stiffness Modulus 60.0 s
|
no data
|
Difference between stiffness moduli 60.0 s
|
no data
|
Estimated m-value 60.0 s
|
0.290
|