Sample Record for 2020-07-23-24
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 214314 DEA: 081F6904 EFIS: 0815000016
QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-79-0.0/15.6
Work Description: COLD PLANE AC PAVEMENT AND PLACE RHMA-G.
Location Description: RIVERSIDE COUNTY NEAR TEMECULA FROM SAN DIEGO COUNTY LINE TO 0.4 MILE EAST OF BUTTERFIELD STAGE ROAD
Contractor Name: All American Asphalt
Contractor Address: P.O. Box 2229, Corona CA, 92878
Resident Engineer: Osama Abdalla Structure Rep.: Unknown
Sample Information
DIME Sample ID: 2020-07-23-24
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Sample Organization Contact: 9512323690
Type of Sample: Department Acceptance
Type of Material: Aggregate
Sample Taken Date: 07/23/2020
Date that the sample was received by the laboratory/organization performing the testing: 07/24/2020
The quantity of what the sample constitutes: 1 bag combined aggregate
A brief description of the sample: AC Drum Aggregate
From where was the sample collected: Manufacturer
Laboratory sample identification: Sample 1
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: AAA-Corona
Material Information
Source Identification (SMARA, name of Pit or Job Site): 91-33-0005::ALL AMERICAN ASPHALT
The fabricator's/manufacturer's product name for the sample: Unknown
The fabricator/manufacturer designation for the sample: Unknown
The plant number: Unknown
A detailed description of where the material sample was collected: belt an chute
Where the material sample would have been placed if not sampled: Unknown
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number: 106835
Lot number: Unknown
Sublot number: Unknown
Aggregate Mix Number:
Test Results
Test 1 of 2
DIME Test ID: 2020-07-23-24-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 07/30/2020
Date Tested: 07/24/2020
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What type of gradation is being tested?
|
Combined Gradation
|
Cumulative percent passing the 2 in. sieve
|
100 %
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
Cumulative percent passing the 3/4 in. sieve
|
98 %
|
Cumulative percent passing the 1/2 in. sieve
|
87 %
|
Cumulative percent passing the 3/8 in. sieve
|
70 %
|
Cumulative percent passing the #4 sieve
|
36 %
|
Cumulative percent passing the #8 sieve
|
19 %
|
Cumulative percent passing the #16 sieve
|
13 %
|
Cumulative percent passing the #30 sieve
|
9 %
|
Cumulative percent passing the #50 sieve
|
6 %
|
Cumulative percent passing the #100 sieve
|
5 %
|
Cumulative percent passing the #200 sieve
|
2.9 %
|
Test 2 of 2
DIME Test ID: 2020-07-23-24-2
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Verified Date: 07/30/2020
Date Tested: 07/24/2020
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified: