Print Report | Back to Sample Detail

Sample Record for 2020-07-28-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 213737 DEA: 07289104 EFIS: 0700021123 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-405-11.9/13.2
Work Description: Rehabilitate the existing Commercial Vehicle Enforcement Facility.
Location Description: LOS ANGELES COUNTY IN CARSON FROM DEL AMO BOULEVARD OVER CROSSING TO VERMONT AVENUE (190TH) UNDER CROSSING.
Contractor Name: POWELL CONSTRUCTORS, INC.
Contractor Address: 8555 Banana Avenue, Fontana, CA 92335
Resident Engineer: Samuel Gallardo Structure Rep.: Bernabe Contreras Jr

Sample Information

DIME Sample ID: 2020-07-28-2
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Sacramento Field Office
Sample Organization Contact: (916) 2058871
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 07/28/2020
Date that the sample was received by the laboratory/organization performing the testing: 07/03/2020
The quantity of what the sample constitutes: 23
A brief description of the sample: High Strength Bolts
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Nucor

Material Information

Rocap Number(s): B431955A N438275A WD7720
Heat Number(s): 100101259
Nut Mfg. Lot Number(s):
Washer Mfg. Lot Number(s):
Bolt Specification: ASTM 325
Bolt Length(s): 1 1/2"
Nut Specification: n/a
Washer Specification: n/a
Finish: Plain
Diameter/Size: 1/2-13
Bolt Mfg. Lot Number: 431955A
Rocap Test Requirement(s):
Lubricant Requirements(s):

Test Results

Test 1 of 2

DIME Test ID: 2020-07-28-2-1
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 08/06/2020
Date Tested: 08/05/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 431955A
Finish Coating Plain
Product Markings A325 USA N
Size .5 in
Bolt Length 1.5 in
Gage Type Pass

Test 2 of 2

DIME Test ID: 2020-07-28-2-2
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 08/06/2020
Date Tested: 08/05/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 431955A
Finish Coating Plain
Product Markings A325 USA N
Size .5 in
Bolt Length 1.5 in
Hardness Reading Scale C Scale
Hardness Reading Average 30.12
Spacing Ok