Sample Record for 2020-07-24-3
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 9999 DEA: 00000000 EFIS: 0000000000 COOP: 99999333399 MINOR: 333333 Permit Numbers: 555555 0400NRT0000
QA Service Level: 1
DIST-CO-RTE-PM: 03-SAC,OMG-888,99,80-0.6-0.6
Work Description: THIS PROJECT RECORD WAS ADDED FOR DIME DEVELOPERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location Description: THIS PROJECT RECORD WAS ADDED FOR DIME DEVELOPERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Contractor Name: YYZ
Contractor Address: 1234 address, Sacramento, CA 95824
Resident Engineer: RE_first RE_last Structure Rep.: SR_First SR_Last
Sample Information
DIME Sample ID: 2020-07-24-3
TL Number from the TL Form:
Sample Submitted By Organization: CT D04 - Hayward DME / District Laboratory
Sample Organization Contact: (510) 507-3456
Type of Sample: Verification
Type of Material: Aggregate
Sample Taken Date: 07/24/2020
Date that the sample was received by the laboratory/organization performing the testing: 07/24/2020
The quantity of what the sample constitutes: 6 bags of virgin aggregate
A brief description of the sample: 1/2" Aggregate for HMA
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Teichert Vernalis
Material Information
Source Identification (SMARA, name of Pit or Job Site): 91-39-0041::VERNALIS WEST & EAST PROPERTIES
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Stockpile @ Plant
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 1/2 inch
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number:
Test Results
Test 1 of 1
DIME Test ID: 2020-07-24-3-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 07/28/2020
Date Tested: 07/24/2020
Submitted By Organization: CT D04 - Hayward DME / District Laboratory
Organization Address: 111 Grand Avenue,
Organization City: Oakland
Organization State: CA
Organization Zipcode: 94623
Organization Email: mohammad.dehghan@dot.ca.gov
Organization Phone: (510) 286-4717
General Comments for this Test: Test for Training
Test Result Compliance:
Additional Comments When Verified: alex.liu@dot.ca.gov
What type of gradation is being tested?
|
HMA Gradation
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
Cumulative percent passing the 3/4 in. sieve
|
100 %
|
Cumulative percent passing the 1/2 in. sieve
|
95.2 %
|
Cumulative percent passing the 3/8 in. sieve
|
78.1 %
|
Cumulative percent passing the #4 sieve
|
59.2 %
|
Cumulative percent passing the #8 sieve
|
43.4 %
|
Cumulative percent passing the #16 sieve
|
28.1 %
|
Cumulative percent passing the #30 sieve
|
17.8 %
|
Cumulative percent passing the #50 sieve
|
10.9 %
|
Cumulative percent passing the #100 sieve
|
6 %
|
Cumulative percent passing the #200 sieve
|
3.5 %
|