*Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Sample Record for 2020-07-13-39


Project Information

Project ID: 88888 DEA: STOCK EFIS: STOCK QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Contractor Address:
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-07-13-39
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Quality Assurance
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 07/13/2020
Date that the sample was received by the laboratory/organization performing the testing: 07/16/2020
The quantity of what the sample constitutes: 89
A brief description of the sample: Prestressing Strand
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:

Material Information

Comments:
Reel/Coil/Pack Number(s):
Number of Coils:
Group Number: 10941
Strand Diameter: .6 in
Grade: 270
Strand Specification: ASTM A 416
Heat Number(s): S0537820, S0580419-3, S0581020, S0581320-2, S0581620-2
Mfg. Lot Number(s): NA
Manufacturer(s): Sumiden Wire

Test Results

Test 1 of 12

DIME Test ID: 2020-07-13-39-1
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 07/23/2020
Date Tested: 07/23/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd
Test General Comments:
Additional Comments When Verified:
Number of Samples 1
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
S0537820S335380-40.2176123957208.228.11.68fsaylor
UTM 120kip
Temperature 72 f
Extensometers no data

Test Results

Test 2 of 12

DIME Test ID: 2020-07-13-39-2
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 07/23/2020
Date Tested: 07/23/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd
Test General Comments:
Additional Comments When Verified:
Number of Samples 1
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
S0537820S335381-50.2196072655684.326.31.78fsaylor
UTM 120kip
Temperature 72 f
Extensometers no data

Test Results

Test 3 of 12

DIME Test ID: 2020-07-13-39-3
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 07/23/2020
Date Tested: 07/23/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd
Test General Comments:
Additional Comments When Verified:
Number of Samples 1
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
S0580419-3S335387-20.2176078958178.6-20757.81.91fsaylor
UTM 120kip
Temperature 72 f
Extensometers no data

Test Results

Test 4 of 12

DIME Test ID: 2020-07-13-39-4
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 07/23/2020
Date Tested: 07/23/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd
Test General Comments:
Additional Comments When Verified:
Number of Samples 1
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
S0580419-3S335385-50.2176072157016.828.71.83fsaylor
UTM 120kip
Temperature 72 f
Extensometers no data

Test Results

Test 5 of 12

DIME Test ID: 2020-07-13-39-5
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 07/23/2020
Date Tested: 07/23/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd
Test General Comments:
Additional Comments When Verified:
Number of Samples 1
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
S0581020S335392-10.2115998955921.928.21.72fsaylor
UTM 120kip
Temperature 72 f
Extensometers no data

Test Results

Test 6 of 12

DIME Test ID: 2020-07-13-39-6
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 07/23/2020
Date Tested: 07/23/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd
Test General Comments:
Additional Comments When Verified:
Number of Samples 1
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
S0581020S335393-30.2136066557375.134.31.91fsaylor
UTM 120kip
Temperature 72 f
Extensometers no data

Test Results

Test 7 of 12

DIME Test ID: 2020-07-13-39-7
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 07/23/2020
Date Tested: 07/23/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd
Test General Comments:
Additional Comments When Verified:
Number of Samples 1
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
S0581320-2S335394-50.2136042357352.5471.88fsaylor
UTM 120kip
Temperature 72 f
Extensometers no data

Test Results

Test 8 of 12

DIME Test ID: 2020-07-13-39-8
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 07/23/2020
Date Tested: 07/23/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd
Test General Comments:
Additional Comments When Verified:
Number of Samples 1
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
S0581320-2S335395-50.2136053955710.328.11.89fsaylor
UTM 120kip
Temperature 72 f
Extensometers no data

Test Results

Test 9 of 12

DIME Test ID: 2020-07-13-39-9
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 07/23/2020
Date Tested: 07/23/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd
Test General Comments:
Additional Comments When Verified:
Number of Samples 1
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
S0581620-2S335407-40.2176073054975.226.42.03fsaylor
UTM 120kip
Temperature 72 f
Extensometers no data

Test Results

Test 10 of 12

DIME Test ID: 2020-07-13-39-10
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 07/23/2020
Date Tested: 07/23/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd
Test General Comments:
Additional Comments When Verified:
Number of Samples 1
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
S0581620-2S335407-10.2156049357138.129.11.88fsaylor
UTM 120kip
Temperature 72 f
Extensometers no data

Test Results

Test 11 of 12

DIME Test ID: 2020-07-13-39-11
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 07/23/2020
Date Tested: 07/23/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd
Test General Comments:
Additional Comments When Verified:
Number of Samples 1
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
S0580419-3S335386-10.2196052856290.926.91.77fsaylor
UTM 120kip
Temperature 72 f
Extensometers no data

Test Results

Test 12 of 12

DIME Test ID: 2020-07-13-39-12
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 07/23/2020
Date Tested: 07/23/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd
Test General Comments:
Additional Comments When Verified:
Number of Samples 1
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
S05081320-2S335394-30.2196047355871.227.61.98fsaylor
UTM 120kip
Temperature 72 f
Extensometers no data